Check for machine vibrations. In the event of a fault, stop the machine immediately and contact the nearest Technical
Assistance Service.
- Should the pump stop, check that consumption of the running motor in amperes is equal to or below that indicated on the
manufacturer's characteristics plate. If this information is available, contact the nearest Technical Assistance Service.
- Empty the pump if it is to remain at a standstill for a certain length of time, especially in cold countries where there is
a risk of freezing.
- Remove the purge cap (10) to empty the pump.
- Every time the pre-filter is opened, clean the seal and its seating of any impurities to ensure airtightness when the cap
is closed (Fig. 5).
- Pump components that, due to their normal use, suffer wear and/or tear must be regularly replaced to ensure good pump
performance. The following table shows the perishables and/or consumables used in the pump and their estimated
working life.
COMPONENT DESCRIPTION
The estimated working life of the parts above has been established according to normal product use and installation conditions.
Follow the instructions in the installation manual to maintain the working life of the pump.
6. REMOVAL
- The motor unit can be removed from the pump body without having to disconnect the pump's suction and return pipes.
- To remove the Motor unit from the pump body, remove the screws joining them together.

7. TROUBLESHOOTING

1. The pump is not primed
2. The pump releases only a small flow of water
3. The pump makes a noise
1 2 3 4 5 6
Installation and General Maintenance Manual
O rings and general seals
Mechanical seal
Bearings
CAUSES
Air entering the suction pipe
Filter cap badly sealed
Inverted motor turning
Wrong voltage
Pre-filter blocked
Load loss in the installation
Pump incorrectly secured
Motor blocked
- POOL PUMPS
ESTIMATED WORKING LIFE
1 year
1 year
1 year
4. The pump will not start
5. The motor is making a noise but will not start
6. The motor is stopped
SOLUTIONS
Check the condition of connections and seals
on the suction pipe
Clean the filter cap and check the condition of the rubber seal
Invert 2 power phases
Check the voltage on the characteristics plate and
that of the mains
Clean the filter
Prevent parts from causing load loss wherever possible
Secure the pump correctly
Remove the motor and contact the technical service