Troubleshooting - Astralpool VICTORIA PLUS SILENT VS Manual De Instrucciones

Ocultar thumbs Ver también para VICTORIA PLUS SILENT VS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. TROUBLESHOOTING

The pump is not primed
1.
The pump releases only a small flow of water
2.
The pump makes a noise
3.
1 2 3 4 5 6
Air entering the suction pipe
Filter cap badly sealed
Inverted motor turning
Wrong voltage
Pre-filter blocked
Load loss in the installation
Pump incorrectly secured
Motor blocked
Increased temperature in the terminal box
due to electric arc
The thermal protection trips
Incorrect terminal box connections
Victoria Plus Silent VS
- ASTRALPOOL
The pump will not start
4.
The motor is making a noise but will not start
5.
The motor is stopped
6.
CAUSES
SOLUTIONS
Check the condition of connections and
seals on the suction pipe
Clean the filter cap and check the condition
of the rubber seal
Invert 2 power phases
Check the voltage on the characteristics
plate and that of the mains
Clean the filter
Prevent parts from causing load loss
wherever possible
Secure the pump correctly
Remove the motor and contact the
technical service
Check the terminal box connections
Connect the cables correctly to the terminal
boxes
Tighten the cable correctly to the terminal
/ Adapt the size of the cable connection to
the terminal box
11

Publicidad

Tabla de contenido
loading

Tabla de contenido