OPERATION
S VARIABLE SERIES - S3V & S4V Models
• To turn the pump off, turn the potentiometer fully counterclockwise to
• To gradually increase the speed to 100% turn the potentiometer clockwise. Graduations
are approximate.
RUN /
F ULT
LED Indicator Lights
RUN/FAULT
RUN
Solid yellow When the pump is running and not in drive fault.
FAULT
Blinking red If pump has a drive fault error.
To Clear: Disconnect, then reconnect power, if FAULT is still present
contact factory for evaluation.
STANDBY/OFF
STANDBY Solid red Pump received a contact closure on the standby inputs.
To Clear: Automatically clears when pump no longer receives a contact
closure on the standby inputs.
OFF
Blinking red When the potentiometer is set to
LEAK
Blinking red When a leak is detected.
To Clear: Clears when the leak detect components are
free of chemical or residue and power to the pump is disconnected,
then reconnected.
POWER
Solid green Mains power is connected.