SETTINGS
LEAK DETECT
page 2 of 3
CALIBRATE THE LEAK DETECT SENSITIVITY
TO BE INSTALLED AND MAINTAINED BY PROPERLY TRAINED
PROFESSIONAL INSTALLER ONLY. READ MANUAL & LABELS FOR ALL
SAFETY INFORMATION & INSTRUCTIONS.
Turn off water system, disable all pumps and depressurize the
system before performing installation. Always wear proper protective safety
equipment when working with metering pumps.
1. Fixed: Put pump in Standby by connecting a jumper wire between terminals Standby
(-) position 19 and Standby (+) position 20.
Variable: Turn pump off, by setting potentiometer to
1
2
3
NC
NC
NC
NC
11
12
13
2. Unplug the pump.
3. Remove tube housing cover from the pump head.
4. Remove the signal cover to allow access to the leak detect adjustment potentiometer.
5. Use a small flat blade screwdriver less than 3 mm and turn the potentiometer
clockwise until there is a clicking sound (approx. 25 rotations).
6. Plug the pump in.
18
S Fixed & Variable Series
continued
4
5
6
7
Transfer
Transfer
Run
NC
Relay
Relay
Relay
(b)
(b)
(a)
NC
NC
NC
NC
14
15
16
17
www.stenner.com
8
9
10
Leak
Run
Leak
Detect
Relay
Detect
(a)
Relay (b)
Relay (a)
Standby
Standby
NC
+
(
)
)
(
18
19
20
.