Solenoid Troubleshooting
Note: Normal operation of the faucet will turn
off water flow if faucet is not touched for 4
minutes.
1. If your spout flashes a red light on then off
and then keeps repeating this,
replace the batteries.
If the spout still flashes a red light, please
replace solenoid and electronics kit**. (see
manual bypass of electronics section*)
2. If your spout displays the proper light, but no
water is coming out of the spout,
a. Verify the handle is in the "on" position.
b. Verify the water supplies are turned to the
"on" position.
c. Move handle to the "off" position. Unscrew
hose from spray head and check for any
debris in the spray head inlet. Move handle
to the "on" position to verify water is reaching
the sprayer. Replace spray head.
d. Move handle to the "off" position. Remove the
hose from the solenoid and move handle to
the "on" position to check for flow coming from
the solenoid. Reconnect hose to solenoid.
e. With handle in the "off" position, remove
the hose from the faucet to the solenoid.
Move handle to the "on" position to check if
water is going through the manual valve and
reaching the solenoid. If water is getting to
Mantenimiento
Tiempo de espera de funciones:
El agua dejará de salir 4 minutos después de la
última vez que tocó la llave de mano o grifo.
Si la lave de agua exhibe muy poco flujo:
A. Quite y limpie el aereador (1) con la llave de
tuerca incluida (2), o
B. CIERRE LOS SUMINISTROS DE AGUA.
Cambie el cartucho de la válvula (5). Usando una
llave de tuercas, asegúrese que la tuerca tapa (6)
esté apretada.*
Si la llave de agua tiene una filtración por
debajo de la manija:
Quite la manija y desenrosque el accesorio de la
manga (7). Usando una llave de tuercas, asegúrese
que la tuerca tapa (6) esté apretada.*
Si la filtración persiste – CIERRE LOS
SUMINISTROS DE AGUA. Cambie el cartucho
de la válvula (5). Usando una llave de tuercas,
asegúrese que la tuerca tapa (6) esté apretada.*
Si la llave de agua tiene una filtración
desde la salida del surtidor – CIERRE LOS
SUMINISTROS DE AGUA. Cambie el cartucho
de la válvula (5). Sando una llave de tuercas,
asegúrese que la tuerca tapa (6) esté apretada.*
* AVISO: Si no aprieta fijamente la tuerca tapa
con una llave de tuercas pudiera resultar en
daño por agua.
Nota: Una cantidad pequeña de agua puede
escurrirse del surtidor o gotear por un período
corto de tiempo después de cerrar el agua. Esto
es una ocurrencia natural causada por la manguera
larga flexible.
the solenoid, but it is not getting through the
solenoid, replace solenoid and electronics kit**.
3. If your LED base indicator is not displaying
any lights,
a. Check to make sure the spout connector, is
attached to the spout and the wire from the
solenoid / electronics kit. If it is disconnected,
or loose (see step 3), reattach and check for
proper operation.
b. Replace batteries.
c. If it is attached and the light still does not
display on the indicator at the base of the
spout, replace the spout assembly**.
*For immediate and temporary operation of your
faucet.
** Refer to part diagram included in this document
for correct RP number.
Cleaning and Care
Care should be given to the cleaning of this prod-
uct. Although its finish is extremely durable, it can
be damaged by harsh abrasives or polish. To clean,
simply wipe gently with a damp cloth and blot dry
with a soft towel. Glass cleaner can be used on SS
(Stainless) finish to remove fingerprints and main-
tain color match. You can avoid turning the faucet
on and off by closing the handle.
Nota: No procure desmontar el cartucho (5). No
hay piezas reparables adentro.
Si la función al tacto deja de funcionar
después del mantenimiento de la llave de agua
o después de hacer las conexiones: Reajuste el
sistema sacando las baterías por 30 segundos y
luego reinstalándolas.
Guía del LED
Si el LED (8) es:
Sólido azul - Válvula solenoide es abierta, la
temperatura del agua es menos de 80 ° F (27 ° C).
Magenta sólida - Válvula solenoide es abierta, la
temperatura del agua está entre 80 ° F (27 ° C) y
110 ° F (43 ° C).
Rojo fijo - Electroválvula está abierto, la temperatura
del agua es superior a 110 ° F (43 ° C).
3 destellos rojos antes de solenoide abre o cierra -
Cambiar las pilas.
Solución de averías del solenoide
Nota: El funcionamiento normal de la llave de
agua cerrará el flujo de agua de esta, si no se
toca durante 4 minutos.
1. Si a su surtidor se le prende y apaga una
luz destellante roja y continua repitiéndose,
cambie las baterías.
37

Publicidad

Tabla de contenido