Pass the electrical cables from mains through the 22 mm (0.87") diameter hole located in
the rear plastic base plate. (5).
Connect the electrical wires to the hand dryer terminal block.
Two phases (N,L) and earth wires must be screwed in the right ways of the terminal block,
as indicated by the engraved letters (6).
After this operation has been done, plastic covers must be placed correctly (10).
Remove the air inlet filter casing (7).
Firmly place the lower screws for fixing the appliance completely (8).
Put the inlet air casing to its location.
Figure 2
-12-