4. Set two 76 mm diameter bands (3) on the pipe loosely (those bands are used for
tightening the swivel pipe and straight pipe, and tightening the solution discharge
lever later).
Assemble the second nozzle (11) with straight pipe (6).
Tighten them with another 76 mm diameter band (3).
5. Put the solution discharge lever (12) onto the pipe.
Make sure that the open side of the lever's base (13) faces the swivel pipe.
Tighten them with the 76 mm diameter band (3).
And then, tighten the swivel pipe (1) and straight pipe (6) with another the 76 mm
diameter band (3).
6. Make sure all clamps are tight.
Adjusting and securing the control handle
1. Put the machine on your back and adjust the shoulder strap (see "Adjusting the
shoulder strap").
2. Slide the control handle (1) along the tube to the most comfortable position.
3. Secure the control handle by turning the knob (2).
Installing and removing the dispersion cover
(optional accessory)
To install the dispersion cover (1), mount the dispersion cover on the top nozzle (2)
so that its protrusion (3) is aligned with the notch (4) in the top nozzle.
Secure the dispersion cover by turning it fully clockwise.
To remove the dispersion cover, follow the above procedure in reverse.
Installing and removing the deflector (optional accessory)
The deflector (1) allows chemicals to be sprayed upward. This helps treatment for
low-growing plants and the underside of leaves of plants.