6. Mist blower operation
While operating the mist blower, adjust the throttle bar so that the wind force is
appropriate for the work location and conditions.
Low speed: 2,800/min
High speed: 7,400/min
The cruise control lever allows the operator to maintain a constant engine RPM
without operating the trigger lever.
Lifting the cruise control lever increases engine RPM.
Lowering the cruise control lever decreases RPM.
Adjusting engine RPM when the cruise control lever is being used:
When increasing RPM:
• Pull the trigger lever to increase engine RPM. Engine RPM returns to its
original setting when the trigger lever is released.
• Increasing the RPM in this manner also increases the cruise control setting.
The cruise control lever lifts simultaneously as the trigger lever is pulled, and
the new cruise control setting will be maintained at the higher RPM.
When decreasing RPM:
• Lower the cruise control lever to the low-speed position
Liquid adjustment knob
Liquid adjustment knob allows a wide range of different discharge rates.
Turn the liquid adjustment knob (1) on the second nozzle to obtain the desired
discharge rate so that the number on the liquid adjustment knob is aligned with the
triangle marking (2).
Discharge rate
Spray holding the straight pipe with the angle of 0 degrees to - degrees to the horizontal.
Knob position
1
2
3
4
* The discharge rate shown in the table is a guide line in case of use of water only. It varies by the liquid being used.
Note:
• Use the figures shown in the above table as a guide line for operation and these may be changed according to the density of chemical
solution used in the solution tank.
Solution discharge lever
To start the solution feeding (A), turn the solution discharge lever (1) horizontally to
the pipe.
To stop the solution feeding (B), turn the solution discharge lever vertically to the
pipe.
7. TRANSPORTING THE MIST BLOWER
Please keep the mist blower in an upright position whenever transporting or storing.
(Refer to the figure.)
Transporting or storing in a position that is not upright may cause oil to spill inside
the mist blower engine. This may result in oil leaks and white smoke from burning
oil, and the air cleaner may become dirty with oil.
DANGER:
When transporting and storing the mist blower, be sure to stop the engine.
With Nozzle 4.5
With Nozzle 0.8
0.3
1
1.6
2.5
Discharge rate (L/min) (mean value)
With Nozzle 0.7
Not used
0.14
21
(2)
(1)
With Nozzle 0.5
0.075
0.060
(A)
(1)
(B)