Technical Data; Symbol Description; Installation Instructions - Hansgrohe Talis Puro Showerpipe 27136000 Modo De Empleo/Instrucciones De Montaje

Ocultar thumbs Ver también para Talis Puro Showerpipe 27136000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries. The shower system may only be used for bathing, hygienic and body
cleaning purposes.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The shower system may only be used for bathing, hygienic and body cleaning
purposes.
The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be oberserved.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of instal-
lation height will also change the minimum height, and that the altered mounting
dimensions must be taken into consideration.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no weak
points.
• The premounted filter insert must be used to ensure a normal flow of the shower
and to prevent dirt from entering through the pipes. Dirt entering can affect the
function and/or lead to damages to the shower. Hansgrohe will not be held
liable for this type of damage.
• If required, the bottom part of the pipe between the fixture and the shower head
can be shortened with a fine-toothed saw.
• The product is not designed to be used with steam baths!
• If the continuous water heater causes any problems, or you have different
water pressures you must install a water limiter to the cold supply, (ordered
separately,article number 97510000).
Fault
Insufficient water
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
Spout temperature does not correspond with tempera-
ture set
Temperature regulation not possible
Instantaneous heater didn't work with thermostat
4
English

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Centre distance:
Connections R1/2:
The product is exclusively designed for drinking water!

Symbol description

Cause
- Supply pressure inadequate
- Filters are dirty (#96922000)
- filter insert shower dirty (#97708000)
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Filters are dirty (#96922000)
- check valve hasn't moved back
- Flow limiter in handshower isn't removed
Assembly see page 12
Do not use silicone containing acetic acid!
Adjustment (see page 14)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Safety Function (see page 14)
Maintenance (see page 18)
The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
Dimensions (see page 19)
Flow diagram (see page 19)
overhead shower
Hand shower
Operation (see page 15)
To empty the overhead shower after use, hold it in a slightly inclined
position.
Cleaning (see page 16)
Spare parts (see page 20)
Special accessories (order as an extra)
tile-matching-disk chrome plated #952391000 (see page 20)
Test certificate (see page 20)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-
thermo cartridge
- Clean filter insert between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 65 ºC
- Exchange thermo cartridge
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
max. 1 MPa
0,15 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
150 ± 12 mm
cold right - hot left

Publicidad

Tabla de contenido
loading

Tabla de contenido