Thermador PROFESSIONAL PRO HARMONY PRG304H Manual De Instalación página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Clearances
{
30" or 36" (762 or 914 mm) Wide Hood
For 30" Ranges
36" or 42" (914 or 1067 mm) for Island
{
36" or 42" (914 or 1067 mm) Wide Hood
For 36" Ranges
42" or 48" (1067 or 1219 mm) for Island
{
48" or 54" (1219 or 1372 mm) Wide Hood
For 48" Ranges
54" (1372 mm) for Island
30" (762 mm) min from bottom of
30" (762 mm) min from bottom of
30" (762 mm) min from bottom of
Overhead Hood to Cooking
Overhead Hood to Cooking
Overhead Hood to Cooking
Surface
Surface
Surface
36" (914 mm) min. if hood
36" (914 mm) min. if hood
36" (914 mm) min. if hood
contains combustible
contains combustible
contains combustible
materials
materials
materials
18" (457 mm)
minimum
*35 ⅞" (911 mm) Min. range height
with leveling legs fully retracted.
*36 ¾" (933 mm) Max. range height
with leveling legs fully extended.
*The range height is adjustable.
The level of the range top must
be at the same level or above
the counter top level.
All manuals and user guides at all-guides.com
Min. Distance Between Overhead Cabinets
Min. Distance Between Overhead Cabinets
Min. Distance Between Overhead Cabinets
o
o
f
f f
Combustible
Combustible
Combustible
Material
Material
Material
30" Range – 30" (762 mm)
30" Range – 30" (762 mm)
30" Range – 30" (762 mm)
36" Range – 36" (914 mm)
36" Range – 36" (914 mm)
36" Range – 36" (914 mm)
48" Range – 48" (1219 mm)
48" Range – 48" (1219 mm)
48" Range – 48" (1219 mm)
Range Width
30", 36", or 48"
(762, 914, or 1219 mm)
For Gas Supply & Electrical Zones see Figure 4.
Zone sizes & positions differ according to model.
Clearances from non-combustible materials are not part of the ANSI Z21.1
scope and are not certified by CSA. Clearances of less than 12" (305 mm)
must be approved by the local codes and/or by the local authority having jurisdiction.
Shaded area above countertop
Shaded area above countertop
Shaded area above countertop
Shaded area above countertop
Shaded area above countertop
indicates minimum clearance
indicates minimum clearance
indicates minimum clearance
indicates minimum clearance
indicates minimum clearance
to combustible surfaces,
to combustible surfaces,
to combustible surfaces,
to combustible surfaces,
to combustible surfaces,
combustible materials
combustible materials
combustible materials
combustible materials
combustible materials
cannot be located within
cannot be located within
cannot be located within
cannot be located within
cannot be located within
this area.
this area.
this area.
this area.
this area.
13" (330 mm)
13" (330 mm)
13" (330 mm)
max. Cabinet
max. Cabinet
max. Cabinet
depth
depth
depth
5" (127 mm)
5" (127 mm)
5" (127 mm)
min. to combustible
min. to combustible
min. to combustible
sidewall material
sidewall material
sidewall material
(both sides)
(both sides)
(both sides)
as defined in the "National Fuel Gas Code" (ANSI Z223.1, Current Edition).
m CAUTION!
m CAUTION!
m CAUTION!
(See Fig. 2 & Fig. 3)
(See Fig. 2 & Fig. 3)
(See Fig. 2 & Fig. 3)
36" (914 mm) min.
36" (914 mm) min.
36" (914 mm) min.
to combustible
to combustible
to combustible
material
material
material
from Cooking
from Cooking
from Cooking
Surface
Surface
Surface
Cooking
Cooking
Cooking
Surface
Surface
Surface
Figure 1: Cabinet Clearances
English 5

Publicidad

Tabla de contenido
loading

Tabla de contenido