Prior to approving the electrical equipment for the use you must run it in a test mode to
ensure it operates properly, has no damages or problems.
→ Turn the device on using the function dial
→ Set the cooking/baking cycle:
Time: 10 minutes
The following conditions must be met for acceptance:
→ → → → The device's lighting comes on automatically after the time is set.
→ → → → The device turns off when the door is opened, and turns on after it is closed.
→ → → → The thermostat for controlling temperature in the device is activated when
the desired temperature is reached. The heating element(s) are
temporarily turned off.
→ → → → The ventilator motor changes the flow direction automatically every 3 minutes.
→ → → → In dual-ventilator devices the motors operate in the same direction.
→ → → → The hose leading to the ventilator has been checked for water leaks.
→ → → → An audible alarm is heard for approx. 15 seconds after the cooking/
baking cycle finishes.
IMPORTANT
When the device is turned on, an audible signal may be heard.
This is normal, and will turn off automatically after a few seconds.
CAUTION!
If the process is interrupted while setting the cooking/baking phase,
set the function dial
- 54 -
Temperature: 150 ° C
M1
in the OFF position.
M 1
.
Steaming : position 2 dial
M 4