Cembre HTEP-S Manual De Uso página 5

Herramientas hidraulicas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

f – Repeat points (d - e) fi ve times, to ensure all air bubbles in the hydraulic circuit are purged into
the reservoir.
g – If the oil level is low, top up as directed in paragraph 5.2.
h – Remove all air from reservoir and fi t cap (01).
i – Assemble main handle (03) to tool body.
If the tool continues to malfunction, return the tool for service/repair as detailed in § 8.
5.2) Oil top up
Every six months check the oil level in the reservoir. If necessary, top up the oil level to the top lip
of the reservoir and remove all air from the reservoir, see 5.1, points a, b, c, and e. Finally, complete
with operations h and i.
Always use clean recommended oil, see § 1.
Do not use old or recycled oil.
Do not use hydraulic brake fl uid.
Ensure that disposal of used oil is in accordance with current legislation.
6. "HTEP..." SYSTEM
The "HTEP..." system consists of:
– a) Hydraulic tool type "HTEP...-S";
– b) n° 2 plungers type "OG ...";
– c) n° 1 gauge type "CAL ...";
– d) Steel case type "VAL HTEP".
The HTEP... system can be supplied in 4 versions for diff erent applications:
SYSTEM TYPE
HTEP
HTEPF
HTEPN
5
(Ref. to Fig. 11)
a) TOOL
HTEP-S
HTEPF-S
HTEPN-S
b) PLUNGER
c) GAUGE
OG 13.2
CAL 19.20
OG 10.5
CAL 135.145
OG 13.2
CAL 175.185
ENGLISH
d) CASE
VAL HTEP

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Htepf-sHtepn-s

Tabla de contenido