Part no
6159932890
Issue no
02
Language English
Date
01/2010
166
Page
18 /
1 - MAINTENANCE LED
The tool is fitted with a maintenance LED that lights as soon as the tool has performed a pro-
grammed number of cycles. This means that it is time to perform maintenance operation. The
number of cycles is set to 500,000.
This alarm does not stop the tool, the operator can go on working, but he/she is to inform the main-
tenance department.
However, you are advised to perform the following operations:
LEVEL 1
Cycles
Replace Angle Head
Pinion - KIT 17
500 000
1 000 000
1 500 000
2 000 000
2 500 000
3 000 000
When the maintenance operation is done, the CVIPFlex software, available in option, offers the possibility to reset
the counter. The maintenance LED then goes off.
2 - TORQUE TRANSDUCER CALIBRATION
The torque calibration is performed using the tool itself, in the Advanced Programming mode (see "PROGRAMMING",
page 10).
3 - ERRORS
In case of tool faulty operation, error codes are displayed. For further information, see "ERROR TABLE", page 19.
4 - TOOL OVERVIEW
For disassembly and part replacement, see "PARTS LIST", page 20.
5 - ELECTRICAL CONNECTIONS
See "PARTS LIST", page 20.
EAP-TFlex tools
CHAPTER 6 - MAINTENANCE
LEVEL 2
Replace keypad-KIT 2
Replace protection-KIT 14
LEVEL 3
Replace planetary
reduction gears-KIT 12
CALIBRATION