Key T5 - Programs Selection And Storing - Cebora EVO 260 T Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The ASME abbreviation are distinguished by a number
plus a letter.
Once the desired position have been selected with M1, by
pressing T4 (<2 s) will accept the selection and move to
the next parameter (L15).
7.6.4
Led L15 - Thickness.
D1 lights and shows the set current; D2 shows
the Thickness corresponding to the current.
Turning M1 the thickness changes and the current will
also be adjusted accordingly.
Obviously the Thickness and corresponding current will
be measured in relation to the Material and welding Posi-
tion settings.
Once the desired Thickness have been selected with M1,
by pressing T4 (<2 s) will accept the selection and move
to the next parameter (L16).
7.6.5
Led L16 - Electrode Diameter.
The electrode Diameter is displayed as a result
of the Material (L13), Position (L14) and Thick-
ness (L15) settings.
D2 shows the recommended electrode in not blinking
way; the operator may use M1 to display other diameters,
G
but these will be shown in flashing mode to indicate that
B
they are not recommended.
Once the desired Diameter have been selected with M1,
L1
L2
L5
L6
L38
L39
L7
T2
T1
L11
L40
L35
T3
L36
T4
L42
L43
L44
L45
38
L4
L3 L10
L9
L8 L13 L12 L14 L15 L16 D1 L17 L41 D2 T5
T7
T8
L22
L24
by pressing T4 for a time longer than 2 s will confirm the
choice and stores also the previous choices made.
By pressing T4 for a time shorter than 2 s will exit the
Synergy without save the choices made, which will be
lost.
7.7

Key T5 - Programs selection and storing.

Operating in Parameter Selection Internal mode
and Job mode.
The Power Source has the ability to store 9 weld-
ing programs (P01.....P09) and call them up through this
key.
Furthermore there is also a program free (D1 off).
7.7.1
Selection.
By pressing T5 for a time shorter than 3 s the program
number following the one in which you are working is dis-
played on D1.
If this has not been stored the message will be flashing,
contrarily will be fixed.
Led L18 lit.
7.7.2
Storing.
Once the program have been selected, by pressing T5 for a
time longer than 3 s, the data will be stored.
The program number indication, on D1, becomes fixed.
L27 L28 L29 L30 L31 L32
L23 L37
L25
L26
Fig. 7
L18
M1
L20
L21
L19
T6
L34
L33
3300036-C

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Evo 330 tEvo 450 t369.80370.80371.80

Tabla de contenido