Emerson LURAY ECO CF860BQ00 Manual Del Usuario página 29

Ventiladores de techo de 60 pulgadas para lugares humedos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

15. Light Kit LED Driver Replacement
15.5
NOTE: You may need help of an assistant to hold
the ceiling cover, coupler cover and upper motor
cover up and away from the motor housing, while
performing the following steps.
Slide the motor coupler cover up the downrod to access
the top of the motor housing (Figure 44).
15.6
Remove the hairpin clip from the clevis pin. Remove the
clevis pin from the downrod (Figure 45).
Retain both the clevis pin and the hairpin clip for future
reinstallation.
Remove the two setscrews, using a Phillips head
screwdriver, from the downrod (Figure 45).
Retain both setscrews for future reinstallation.
15.7
Remove the three upper motor cover screws, using a
Phillips head screwdriver (Figure 46).
Retain the three screws for future reinstallation.
Slide the upper motor cover up to expose access to the
light kit driver.
Figure 44
4.5" DOWNROD
CLEVIS
PIN
REMOVE
PHILLIPS HEAD
SETSCREWS (2)
Figure 45
UPPER MOTOR
COVER
Figure 46
29
(Continued)
COUPLER
COVER
UPPER MOTOR
COVER
MOTOR
COUPLING
HAIRPIN
CLIP
UPPER MOTOR
COVER SCREWS (3)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Luray eco cf860pt00Luray eco cf860ww00

Tabla de contenido