CEBORA S.p.A.
3
INSTALLATION.
This equipment must be used solely for welding operations.
It is essential to pay especially close attention to the chapter on SAFETY PRECAUTIONS in this
Instruction Manual, par. 1.
The equipment must be installed by qualified personnel.
All connections must be carried out in compliance with current standards and in full observance of
current safety laws.
3.1
Power Source installation.
For reference see fig. 2 and 4.
 Remove the Power Source (21) from its packing and place it in an area that ensures good stability, and
efficient ventilation so as to prevent metal dust from entering.
 Place the Robot Interface (25) inside the Robot Control Cabinet (5), following the instructions
provided in the Robot Interface Instruction Manual.
 Connect the Power Source (21) to the Control Panel (24) using the connection cable (1).
 Connect the Power Source (21) to the Robot Interface (25) using the signal cable (3) and the
CANopen cable (4) (the latter is included in the Robot Interface).
 Connect the Power Source (21) to the Wire Feeder (8) by means of the extension (2).
NOTE: avoid coiling the extension (2) to reduce to a minimum the inductive effects that could affect the
results in pulsed MIG/MAG welding.
- Connect the ground cable of the welding system to the Power Source BO terminal.
- Mount the plug on the power cord, being especially carefully to connect the yellow/green conductor to
the earth pole.
- Make sure that the supply voltage corresponds to the rated voltage of the Power Source.
- Size the protective fuses based on the data listed on the Power Source technical specifications plate.
- Complete the remaining connections of the other Welding System equipment, consulting the relevant
Instruction Manuals in par. "Installation".
3.2
Welding System power up.
For reference see fig. 2 and 4.
 Power up the Welding System using the BU switch of the Power Source.
 System powered; on Control Panel all leds and display light on (lamp test).
 After one second, the display O reads "Art", and display P reads the Power Source code (es.:"295").
 After one second, Control Panel displays show the MASTER, PANEL and MOTOR programs
versions indications (for displaying modes see Control Panel Instruction Manual).
 Subsequently, Control Panel returns in the state as set before the last time the unit was shut off.
 After one second the BU switch is closed, the fan on the Power Source runs for 10 seconds, then stops.
 Depending of its setup Cooling Unit may start running.
NOTE: The Cooling Unit is preset by the factory to OFF. Change this setting if a water-cooled torch is
used (see Cooling Unit Instruction Manual).