in the ON position, after a minute, the valve opens al-
lowing suction of the stale air. By placing the switch in
the OFF position, the valve closes after 100 seconds.
Before installing the cooker hood: assembly the
electrovalve kit K as shown in fig.2.
The electrovalve kit K can also be turned at 180°.
• Installation:
Depending on the version of the appliance you have,
proceed with the installation of type "A" (Fig.3) or type
"B" (Fig.4):
• Fixing the hood to the lower part of the wall
cabinet:
Type "A": This type of appliance must be fitted inside
a cabinet or inside another type of support structure.
To fix it in place, use 4 screws which are suitable for
the type of cabinet, making holes in accordance with
the diagram shown in Fig.1.
Type "B": For this type of hood make sure the thickness
of the cabinet falls within the range of values listed
in (Fig.4). Fit the cooker hood in the cabinet (Fig.4)
and make sure the springs are fixed in place well. Fix
the cooker hood to the cabinet securely by using a
screwdriver to tighten the screws until the appliance
is flush with the cabinet (Fig.5).
To fit the appliance correctly, align the front panel of
the cooker hood with the cabinet door and adjust
spacer L using screws P (Fig.7 ), then ensure the ap-
pliance meets the cabinet at the rear.
• Extraction through an outside wall:
The appliance expels the fumes through an outside
wall or a duct. It is necessary to buy a telescopic pipe
in accordance with the standards in use (inflammable)
and connect it to flange H (Fig.3 - Fig.4).
• Adjusting the damper for proper extraction
(Fig.8):
The basic ventilation has 4 setting options (A1-4),
to which there are 4 corresponding forced settings.
BEWARE: The adjustment is done with closed valve.
Remove the grease filter and loosen the screw (A),
adjust the valve as needed (see the overview below).
Make sure the two plates (P1-P2) are parallel, tighten
the screw and reinstall the grease filter.
USE AND MAINTENANCE
• We recommend that the cooker hood is switched
on before any food is cooked. We also recommend
that the appliance is left running for 15 minutes after
the food is cooked, in order to thoroughly eliminate
all contaminated air. The effective performance of
the cooker hood depends on constant maintenance;
the anti-grease filter and the active carbon filter both
require special attention.
• The anti-grease filter is responsible retaining the
grease particles suspended in the air, therefore it is
subject to clogging with variable frequency according
to the use of the appliance.
- To prevent the danger of possible fires, at least every 2
months one must wash the anti-grease filters by hand
using non-abrasive neutral liquid detergents or in the
dishwasher at low temperatures and on short cycles.
- After a few washes, colour alterations may occur. This
does not give the right to claim their replacement.
• Clean the hood frequently, both internally and
externally, using a cloth dampened with denatured
alcohol or neutral liquid detergents that are non
abrasive.
• The lighting .system is designed for use during
cooking and not for the prolonged general lighting
of the room. The prolonged use of the lighting system
significantly decreases the average duration of the
bulbs.
• If the appliance is equipped with courtesy lights it is
possible to use them for general room lighting for a
prolonged amount of time.
• Attention: the non compliance with the hood clean-
ing warnings and with the replacement and cleaning
of the filters entails risk of fires. One therefore recom-
mends keeping to the suggested instructions.
• Control (Fig.9)
A. Press ON / OFF light
B. Valve opening / Valve closing
• Replacing the lamps
Only use lamps of the same type and wattage installed
on the device.
THE MANUFACTURER DECLINES ALL RESPONSIBIL-
ITY FOR EVENTUAL DAMAGES CAUSED BY BREACH-
ING THE ABOVE WARNINGS.
GENERELLE OPLYSNINGER
Læs omhyggeligt indholdet af denne brugsanvisning,
da den giver vigtige oplysninger vedrørende sikkerhe-
den ved installering, brug og vedligeholdelse.
OPLYSNINGER VEDRØRENDE SIKKERHED
1. Udvis forsigtighed hvis der samtidigt med emhæt-
ten er en varmekilde eller flamme i funktion, som er
afhængig af luften i omgivelserne og forsynet med
energi, der ikke er elektrisk, eftersom emhætten
fjerner den luft fra omgivelserne, som flammen eller
varmekilden har brug for til forbrænding. Det negative
tryk i lokalet må ikke overstige 4 Pa (4x10-5 bar). For
størst mulig sikkerhed, sørg for en passende ventila-
tion af rummet. Hvad angår udsugningen til eksterne
omgivelser følg de gældende normer.
Før modellen tilsluttes el-nettet:
- Kontrollér informationsetiketten (placeret indeni
apparatet), for at sikre, at spændingen og styrken
er i overensstemmelse med el-nettet og at stikkon-
takterne er egnede. Hvis De er i tvivl, konsultér en
kvalificeret elektriker.
- Hvis forsyningsledningen er beskadiget, skal den
udskiftes med en ledning eller en særlig samling fra
fabrikanten eller et autoriseret servicecenter.
2. Pas på!
I nogle situationer kan elektriske apparater udgøre
en fare.
A) Undgå at kontrollere filtrenes tilstand mens
- 12 -
DANSK
DK