The Troubleshooting table indicates measures to be taken if the sensor stops working.
LED/fault pattern
WEO:Green LED flashes
Switching outputs do not
behave in accordance with
table 5
Not all blue LEDs light up.
No object in beam path, no
output signal
Yellow LED flashes
A71
A72
V1.1
2 bytes
Byte 0: bits 15... 8
Byte 1: bits 7... 0
Q
/ Boolean
L1
Qint.1 /
Boolean
2 ... 15 /
2 ... 15 /
[time
[counter
[length /
value] /
speed
ment
UInt 14
measure‐
ment] /
SInt14
Cause
IO-Link communication
1. Change of the configuration
2. Short-circuit
a) Insufficient alignment
b) Contamination of the opti‐
cal surfaces
c) Particles in the light beam
d) Distance between sender
(WS) and receiver (WE) is
too large
Test input (Test) is not con‐
nected properly
Distance between sender
(WS) and receiver (WE) is too
large / Beam of WS is not
completely on WE or WE is not
aligned to WS
O P E R A T I N G I N S T R U C T I O N S | WSE26
TROUBLESHOOTING
A73
A75
4 bytes
Byte 0: bits 31...
24
Byte 1: bits 13...
16
Byte 2: bits 15...
8
Byte 3: bits 7... 0
Q
/ Boo‐
Qint.1 / Boolean
L2
lean
2 /
2 ... 7 / [empty]
Qint.1 /
Boolean
3 ... 15 /
8 ... 31 / [carrier
[time
load] / UInt 24
measure‐
ment
value] /
UInt13
Measures
None
1. Adjustment of the configura‐
tion
2. Check electrical connections
a) Check alignment
b) Cleaning of the optical sur‐
faces.
c) Avoid contamination in the
air as far as possible
d) Check sensing range
Check connection of the test
input. When using female cable
connectors with LED indicators,
make sure the test input is
assigned correspondingly.
Check sensing range,
see
figure 13
Check alignment