Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
OPERATING INSTRUCTIONS
7.2
Sensing range adjustment
en
7.3
Additional functions
8

Troubleshooting

36
O P E R A T I N G I N S T R U C T I O N S | RSB - Roller Sensor Bar
mm (inch)
20
(0.79)
1
2
10
(0.39)
0
–10
(–0.39)
–20
0
40
80
(–0.79)
(1.57)
(3.15)
Distance in mm (inch)
Figure 7: Active light beam width
Black, 6%
1
Gray, 18%
2
White, 90%
3
Sensing range is not able to be set. The sensor has been adjusted to the maximum
sensing range by the factory and is ready for operation.
IO-Link
The sensor can be used in standard I/O mode (SIO) or IO-Link mode (IOL). All automa‐
tion functions and other parameter settings are effective in IO-Link mode and in stand‐
ard I/O mode (exception: Time stamp). Output of binary switching signals in standard
I/O mode via pin 4 / black wire and via pin 2 / white wire.
Information on the IO-Link functions can be found in the enclosed IO-Link photoelectric
sensor operating instructions or downloaded from
number.
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 7: Troubleshooting
LED/fault pattern
Green LED flashes
Digital outputs not according to
graphic
table 14
Yellow LED lights up, no object
in the path of the beam
3
120
160
(4.72)
(6.30)
www.sick.com
Cause
IO-Link communication
1.
IO-Link communication
2.
Change of the configura‐
tion
3.
Short-circuit
Excessive background remis‐
sion / Light emission (optics)
is dirty.
under the device part
Measures
-
1.
None
2.
Adjustment of the con‐
figuration
3.
Check electrical connec‐
tions
Check the background for
highly reflective Objects /
Cleaning of the optical surfa‐
ces.
8027085/2022-05-31 | SICK
Subject to change without notice

Publicidad

Tabla de contenido
loading

Tabla de contenido