6
COMMISSIONING
6.3

Setting

7

Troubleshooting

en
8

Disassembly and disposal

20
O P E R A T I N G I N S T R U C T I O N S | WLF4F
B
Sensing range max. in m
C
Maximum distance range from reflector to sensor (operating reserve 1)
D
Recommended distance range from reflector to sensor (operating reserve 3.75)
blue
Recommended sensing range for the best performance
Sensitivity adjustment
WLF4Fx-xxxxxxA0Zxx:
Sensor which it is not possible to set: the sensor is adjusted and ready for operation.
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 12: Troubleshooting
LED/fault pattern
Switching outputs do not
behave in accordance with
table 5
Yellow LED flashes
No object in beam path, no
output signal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
Cause
1. Change of the configuration
2. Short-circuit
Distance between sensor
and reflector is too large /
light beam is not completely
aligned to the reflector /
reflector is not suitable / Front
screen and/or reflector is con‐
taminated.
Test input (Test) is not con‐
nected properly
Measures
1. Adjustment of the configura‐
tion
2. Check electrical connections
Check sensing range / check
alignment / SICK reflector is
recommended / Cleaning of
the optical surfaces (sensor
and reflector).
Check connection of the test
input. When using female cable
connectors with LED indicators,
make sure the test input is
assigned correspondingly.
8027380.1DTW /2021-12-13 | SICK