Disassembly And Disposal; Maintenance; Technical Data - SICK WSE26 Instrucciones De Uso

Ocultar thumbs Ver también para WSE26:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
10

DISASSEMBLY AND DISPOSAL

10
Disassembly and disposal
en
11

Maintenance

12

Technical data

Sensing range max.
Light spot size / distance
Supply voltage U
B
Ripple
Current consumption
Output current I
max.
Max. response time
Switching frequency
30
O P E R A T I N G I N S T R U C T I O N S | WSE26
LED/fault pattern
Yellow LED lights up, although
an object is in the path of the
beam.
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
Clean the optical interfaces using a plastic cleaner, do not use acetone or methy‐
lated spirits.
Check the fittings and plug connectors
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
Cause
The beam of light of a pho‐
toelectric through-beam sen‐
sor hits the receiver of
another (neighboring) photo‐
electric through-beam sensor
WSE26P
0 m ... 60 m
Ø 90 mm / 8 m
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
1)
< 50 mA
2)
≤ 100 mA
≤ 500 μs
3)
1,000 Hz
4)
Measures
Swap the sender and receiver
arrangement at every sec‐
ond through-beam photoelec‐
tric sensor and ensure that
there is sufficient distance
between the through-beam
photoelectric sensors
WSE26I
0 m ... 60 m
Ø 110 mm / 8 m
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
1)
< 50 mA
2)
≤ 100 mA
≤ 500 μs
3)
1,000 Hz
4)
8020358.1DS8/2021-11-24 | SICK
Subject to change without notice

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

W26

Tabla de contenido