►7.3. Assemble the manometer (not supplied,
en
see "ACCESSORIES").
►7.4. Switch the heater on.
it
►7.5. Act on the regulation screw by turning it
de
clockwise to increase the pressure and anti-
clockwise to decrease it (B).
es
►7.6. Remove the manometer and restore the
screw/cap (A).
fr
nl
8. CLEANING THE TANK FILTER
(SEE FIG. 8)
pt
DEPENDING ON THE QUALITY OF THE FUEL
THAT IS USED, THE TANK FILTER MAY HAVE
da
TO BE CLEANED.
fi
►8.1. Remove the cap (A) from the tank.
►8.2. Extract the filter (B) from the tank.
no
►8.3. Clean the filter (B) with clean fuel, paying
sv
attention not to damage it.
►8.4. Re-mount the filter (B) in the tank.
pl
►8.5. Close the cap (A).
ru
9. PRESERVATION AND
cs
TRANSPORT
I ORDER TO KEEP AND/OR TRANSPORTAR
hu
THE HEATER IN THE BEST WAY, STHE
FOLLOWING
PROCEDURE
sl
FOLLOWED.
tr
►9.1. Empty the fuel tank (some models have
a draining cap on the bottom of the tank. In
hr
this case, remove the drain cap and empty
lt
the fuel).
►9.2. If the presence of residues is noted, pour
lv
clean fuel into the tank and drain off again.
►9.3. Close the tank cap and/or the draining
et
cap and dispose of the fuel appropriately
ro
according to the Standards in force.
►9.4. In order to keep the heater in the best way
sk
possible, it must be kept on a level surface to
prevent the escape of fuel and in a dry place
bg
away from any possible external threats.
uk
bs
el
11. PREVENTIVE MAINTENANCE SCHEDULE
zh
WARNING: BEFORE PERFORMING ANY MAINTENANCE OR REPAIRS, DISCONNECT
THE POWER SUPPLY CABL FROM THE MAINS AND MAKE SURE THAT THE HEATER IS
COMPONENT
Fuel tank
Filters
MUST
BE
MAINTENANCE FREQUENCY MAINTENANCE PROCEDURE
Empty and rinse the tank with clean
fuel every 150-200 working hours
Clean or replace every 500 working
hours or when necessary
10. ROOM THERMOSTAT
►►10.1. MODELS PRE-SET FOR REMOTE
ROOM THERMOSTAT:
(SEE FIG. 9)
For models preset for remote room thermostat,
remove the cover connected to the heater (A),
connect the thermostat (B) (optional) and set
the desired room temperature.
►►10.2. MODELS WITH ROOM
THERMOSTAT INSTALLED ON THE
CONTROL PANEL:
(SEE FIG. 10)
For models with room thermostat installed on
the control panel, when the knob (B) is turned
the desired temperature starts flashing on the
display (A) for a few seconds, after which the
display shows the room temperature. When the
knob (B) is turned completely to the right, the
display (A) shows "CH", after which the heater
works continuously.
►►10.3. MODELS PRE-SET FOR REMOTE
ROOM THERMOSTAT AND ROOM
THERMOSTAT INSTALLED ON THE
CONTROL PANEL:
(SEE FIG. 9-10)
For models preset for remote room thermostat
and room thermostat installed on the control
panel, remove the cover connected to the heater
(SEE A FIG. 9) and connect the thermostat
(SEE B FIG. 9) (optional). For correct heater
operation, completely turn the knob to the
right (SEE B FIG. 10), the display (SEE A FIG.
10) shows "CH", after which set the desired
temperature on the remote room thermostat.
COLD.
Empty and rinse the tank with
clean fuel (SEE PAR. 9)
Contact the technical service
center