Main Supply
Voltage
Current type
Connected load
Protection (slow)
Type of protection
Protective class
Maximum allowed net impedance
Water connection
Max. feed temperature
Min. feed volume
Suck height from open container (20 °C)
Max. feed pressure
Inlet hose diameter (min.)
Inlet hose length (min.)
Performance data
Water flow rate
Operating pressure of water (using standard
nozzle)
Max. excess operating pressure (safety
valve)
Max. operating temperature of hot water
Detergent suck in
Burner performance
Maximum consumption of heating oil
Max. recoil force of trigger gun
Size of standard nozzle (UX)
Values determined as per EN 60335-2-79
Noise emission
Sound pressure level L
pA
Uncertainty K
pA
Sound pressure level L
+ Uncertainty K
WA
(UX)
Hand-arm vibration value
Hand spray gun
Spray lance
Uncertainty K
Fuel
Fuel
Amount of oil
Oil grade
Dimensions and weights
Length x width x height (UX)
Typical operating weight (UX)
Fuel tank
All manuals and user guides at all-guides.com
Technical specifications
V
Hz
kW
A
--
--
Ohm
°C
l/h (l/min)
m
MPa (bar)
Inch
m
l/h (l/min)
MPa (bar)
MPa (bar)
°C
l/h (l/min)
kW
kg/h
N
--
dB(A)
dB(A)
dB(A)
WA
m/s
2
m/s
2
m/s
2
--
l
Engine oil
15W40
mm
kg
l
– 8
EN
HDS 5/11
HDS 5/13
220
230
240 220 230 240 220
1~ 50
1~ 50
2,2
2,6
16
16
13
16
16
IPX5
IPX5
I
I
--
--
30
30
500 (8,3)
550 (9,2)
0,5
0,5
0,6 (6)
0,6 (6)
1/2
1/2
7,5
7,5
450 (7,5)
500 (8,3)
11,0 (110)
12,5 (125)
16,5 (165)
18,0 (180)
80
80
0-33 (0-0,6)
0-33 (0-0,6)
26
29
2,7
3,1
18,1
21,4
032 (033)
034
76
76
3
3
94 (93)
93
2,4
1,0
1,4
1,1
0,3
0,3
Fuel oil EL or Die-
Fuel oil EL or
sel
Diesel
0,1
0,1
Order no. 6.288-
Order no.
050.0
6.288-050.0
618 x 618 x 994
618 x 618 x 994
(1163)
(1163)
70 (72)
74 (76)
6,5
6,5
HDS 5/15
230
240
1~ 50
2,7
13
16
16
13
IPX5
I
(0.380+j0.237)
30
500 (8,3)
0,5
0,6 (6)
1/2
7,5
450 (7,5)
15,0 (150)
20,0 (200)
80
0-33 (0-0,6)
26
2,7
20,8
028
77
3
94
0,9
1,1
0,3
Fuel oil EL or
Diesel
0,2
Order no. 6.288-
050.0
618 x 618 x 994
(1163)
76 (78)
6,5
21