Trial Run; Maintenance; Technical Data - Dustcontrol S34000 Traducción Del Manual De Instrucciones De Servicio Original

Ocultar thumbs Ver también para S34000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
1. Mount the bottom cone on the legs.
Adjust the height of the legs according to which discharge cone / container is selected.
2. Mount the inlet module on the bottom cone. Lock it with the locking ring.
3. Mount the module ring on the inlet module. Lock it with the locking ring.
4. Mount the filter plate on the module ring. Lock it with the locking ring.
5. Mount 4 st filter. Locked them with 4 filter-locking ring(s).
6. Mount the filter cleaning unit (tank) on the filter plate. Then lock with star knob.
7. Mount the outlet module on the filter plate. Lock it with the locking ring. Route cable through bulkhead bushing. Connect
compressed air hose.
8. Install the cover on the outlet module. Lock it with the locking ring.
After mounting the filter cyclone, the following must be done:
1. Connect inlet and outlet.
2. Connect the filter cleaning to compressed air and control voltage from the control cabinet. For values in detail see Technical
data.

Trial run

Make sure that the vacuum generator is correctly installed and that the inlet and outlet are connected to the piping system. The
piping system between the filter cyclone and the vacuum generator must be free of particles. Check the grounding of the piping
system between the units in the system.
Verify that the output device is securely fastened so that no air is sucked in that way and that the barrel is properly grounded.
Verify that the automatic filter cleaning works.

Maintenance

It is important that the cyclone's filters are replaced as they can no longer be cleaned effectively. The intervals between the
changes depend entirely on the material being sucked, the flow of the system and the operating time.
Filter replacement
Filters must be changed at least once a year. Depending on operating conditions and shifts, they may need to be replaced more
often. Do not expose unprotected dust to hazardous dust.
Filter replacement may only be performed by trained personnel. Use a protective mask and suitable equipment.
1. Turn off and lock the vacuum producer's circuit breaker.
2. Put on safety gear.
3. Empty the compressed air-tank.
4. Remove the cover of the dust separator.
5. Remove the filters and put them in a plastic bag. Seal the bag.
6. Vacuum filter plate and casing.
7. Put the new filters in place, and put the cover back on the dust separator.
Explosion panel
Information regarding maintenance of the explosion panel can be found in a separate document from the supplier.

Technical data

Technical data
H x W x D [mm]
Weight [kg]
Inner diameter [mm]
Inlet [mm]
Outlet [mm]
Maximum recommended air flow [m
S34000
2700 x 1150 x 1225
225
Ø 1046
Ø Optional
Ø 250
3
/h]
4000
S34000, Art no. 99055-A
15

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido