5 Appliance dimensions
Appliance dimensions
Appliance dimensions
BS470/BS471
BS474/BS475
BS484/BS485
6 Prior to installation
Prior to installation
Carry out these steps to prepare your appliance for instal-
Prior to installation
lation.
6.1 Preparing the cabinet
Requirement: The built-in cabinet must be heat-resistant
up to 195°F (90°C), and adjacent cabinet fronts up to
160°F (70°C).
Ensure that the junction box is located outside of the
1.
cabinet opening.
Carry out any necessary cut-out work on the cabinet
2.
and remove the shavings. Shavings may impair the
function of electrical components.
Secure any unsecured cabinets to the wall using a stan-
3.
dard bracket.
Only install the appliance high enough that the cus-
4.
tomer can remove the accessories effortlessly.
The cabinet base must be flat and capable of support-
5.
ing the weight of your unit. Refer to the appliance
weight table for the requirements of your oven.
→ Page 4
6.2 Water supply
The appliance is backflow-proof (VDE tested). Connection
valves with backflow preventers are not required.
Follow the regulations of the local water utility provider.
¡
Only connect the appliance to the water supply using
¡
the included water connection set. Do not reuse an ex-
isting water connection set of a different appliance.
Connecting the water supply
Only connect the appliance to a cold water connection
▶
that is always accessible and is not located directly be-
hind the appliance.
– Inlet hose: Connection thread ISO228 -
G ¾'' (26.4 mm)
– Water pressure: 0.2 - 1.0 MPa (2-10 bar)
– Flow rate: Min. 2.6 gal (10 liters) per minute
6.3 Waste water connection
The appliance has a drain hose.
Information on the drain hose:
The inner diameter of the drain hose is 1½" (38 mm).
¡
Make sure that the outlet hose is not longer than 16.5 ft
¡
(5 m).
Connecting the drain hose
Provide an odor trap to the waste water connection.
1.
Make sure that the connection to the odor trap is always
accessible and not directly behind the appliance.
Appliance dimensions en-us
5