Tool Specifications

Laser distance meter
The symbols on the device have the following meaning:
Laser irradiation
Do not look into the beam
Laser class 2
according to IEC 60825-1: 2007
Max. power output:
Wavelength:
620 – 690 nm
Order number
Measuring range, direct
Measuring range,
with target plate
Inclination measurement
Measuring accuracy, typ.
– Distance measurements
– Inclination measurements
Smallest display unit
Laser point Ø in
10/50/100 m
Automatic shut-off
Laser/device
Memories of measured
values, amount
Automatic release/timer
Batteries: Micro/LR03
Battery operating life
Protection class
Storage temperature
Operating temperature
Weight, approx.
* For the following situations, using a target plate is recom-
mended already for closer working ranges:
- Poorly reflecting surfaces
- Reflecting surfaces (glass, metal, etc.)
- Bright ambient light, such as direct sun light
** Under unfavourable conditions, e.g., for temperature
alterations, for a poorly reflecting surface or bright ambi-
ent light, the error of measurement can be up to 3 mm.
For working ranges in excess of 30 m, the accuracy
declines by 0.1 mm/m.
The device is intended for measuring distances and
WDM 101
inclinations, as well as for the calculation of areas
and volumes. The measured values determined by
the device may not be used to control or trigger
other equipment, machinery or systems. The device
is not suitable for operation in hazardous areas.
For damage caused by usage other then
intended, the user is responsible.
<1mW
0714 640 710
1 Laser, switched on
0.05 m – 80 m*
2 Number of memory location
3 Measuring level (front/rear)
100 m
4 Illumination
± 45°
5 Circumference
6 Mark-out function
± 1.0 mm**
7 Wall surface
± 0.3°
8 Pythagoras I, II and III
0.1 mm
9 Ceiling surface
10 Information
11 Main display
6/30/60 mm
12 Unit of measure
13 Displays for intermediate values
180 s/360 s
14 Menu for Units, Reset, Tripod, Beep
ON/OFF
20
15 Continuous laser beam
5 s – 60 s
16 Solid angle, inclination, horizontal dis-
2 x 1.5 V
tance via inclination
5 000 distance
17 Area/volume
measurements
18 Timer
IP 54
19 Battey status display
(IEC60529)
20 Memory function
21 Type plate
–25 ... +70 °C
–10 ... +50 °C
0.12 kg
Keypad/Pushbuttons
22 On/Off switch, distance measurement,
tracking
23 Surface measurement/volume measure-
ment
24 Add button for calculations
25 Solid angle measurement
26 Change measuring level

Use as Intended

Display Symbols

15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

0714 640 710

Tabla de contenido