drums or solvent. In order to maintain the high safety standard
of the unit, it is important that these instructions are followed.
– Do not operate the unit until you have read and fully under-
stood this entire User's Manual.
– The unit should be isntalled as described in the instructions.
– The unit should be used as described in the instructions.
– The unit should be maintained as described in the instructions.
– Only original spare parts may be used.
– This User's Manual must be available and in legible condi-
tion in close proximity to the unit. Every user shall know
where to find the User's Manual.
– Operating instructions should be formulated on the basis of
this Users Manual, and translated into the language spoken
by the employees.
– Do not modify or in any way alter the unit.
– Do not operate the unit unless it is properly vented. Do not
operate the unit if the extraction of vapors is insufficient.
– Avoid contact with liquid and vapor. Refer to the solvents'
MSDS (Material Safety Data Sheet).
– Wear chemical goggles or similar, to protect your eyes.
Wear chemical-resistant gloves to prevent skin-contact.
Wear chemical-resistant clothing to protect against spills
or splash.
– Personnel suffering from respiratory problems or allergies
to solvents used, must not operate the machine.
– Clean up spills immediately. Solvent vapours are heavier
than air and can spread a long way. They may also collect
in pits or other low areas.
– Do not smoke, eat or drink while close to the unit.
– The unit is equipped with a safety valve that will interrupt
the automatic wash cycle if the lid is opened before the
wash cycle is completed.
– A fire extinguisher must always be kept nearby when work-
ing with flammable solvents. Do not use water.
– Spray guns or any other paint equipment items cleaned
in the unit must be suitable for cleaning in a Zone 1 area
(ref. Category 2 according to EN 13463-1/2001). If unsure,
please contact the spray gun manufacturer.
– The unit must be properly grounded using the attached
grounding cable. If plastic drums are used, the openings
should be wiped off with a damp cloth, to avoid static
electricity, before inserting or removing any hoses or other
equipment.
TECHNICAL DATA
Manufacturer
6
HEDSON TECHNOLOGIES AB
Hammarvägen 4
SE-232 37 Arlöv
Sweden
Tel.: +46-40- 53 42 00
Type of machine:
DRESTER X-SERIES DIX22
Permitted solvents
See section "Permitted Solvents"
Max solvent volume
30 + 30 + 30 + 30 litres
of machine
(Check for local regulations concerning max allowed volume for
keeping solvent in the unit)
Maximum drum size
60 litres
Compressed air needed
7–12 bar (110–180 psi)
180 l/min (6 cfm) 2 pumps
460 l/min (17 cfm) including
AIRVENT 11660 in operation
Ventilation capacity required 240-600 m
-> 0,2-0,5 m/s (0,7-1,6 fps)
Pump capacity
10 l/min
Solvent pressure
2 bar (30 psi)
Weight
95 kg (209 lb)
Overall dimensions
Height: 1510 mm (59,5")
Width: 1185 mm (46,7")
Max depth: 650 mm (25,5")
Depth at the floor: 610 mm (24")
Extractor diameter
125 mm (5")
Sound pressure level
<70 dB(A)
/h (141-353 cfm)
3
230505 rev3 2022-02-01