3.1

Putting the PRCD switch into operation

Only suitable for AC current! Note the mains network voltage!
Perform the following test procedure on the PRCD switch before every putting into operation of
the device:
1. Connect the PRCD plug connector with the socket.
2. Press on RESET. The indicator switches to ON.
3. Pull the plug connector out of the socket. The display switches itself off.
4. Repeat 1. and 2.
5. Press on TEST. The indicator switches itself off.
6. Press on RESET to switch the device on.
These protective device protect against faults in the attached device, not against
such faults in the preceding plant!
4

Function of the Unit

4.1
Overview
Drive shaft
1
On/off switch
2
Power cable with PRCD switch
3
Gear selector switch
4
4.2
Start of operation
Clamping into the drill rig (picture 1)
RODIACUT 250:
 Lock the feed gear on the drill rig.
 Use the supplied screws to fasten the swallowtail plate to the drill motor.
Please pay attention to the correct position of the feather key groove, bores and fitting
position!
 Slide the motor from the top as far as it will go into the swallowtail guiding on the drill rig and
tighten using both star handles.
 Check the tight fit of the motor.
RODIACUT 400 PRO:
 Remove the feed gear from the drill rig.
 Fasten the feed gear to the drill motor by means of the screws and a T-handle with ball end
attached to the drill rig.
Please pay attention to the correct position of the feather key groove, bores and fitting
position!
 Slide the motor together with the feed gear from the top into the guideway on the drill rig.
 Check the tight fit of the motor.
For this please read the drill rig instruction manual!
Changing the drill bit (picture 2)
Please wear protective gloves when changing the drill bit. The drill can become hot after
being in use for a longer period of time!
 Use an open-ended spanner (SW 36) to hold the drive shaft (1) and release and unscrew
(right-hand thread) the drill bit using an open-ended spanner (SW 24 for G 1/2" bits; SW 41
for 1.1/4" UNC bits).
Information: In the case of drill bits with a 1.1/4" UNC screw thread it is recommended to place
a copper ring (No. FF35190) between the drill motor and the drill bit. It is then easier to separate
14
Drill rig fitting
5
Water supply
6
Water supply "Gardena"