ACO202/ECO202
7.2

Meaning of the LED display

EN
LED display
Green LED off.
Green LED lights up.
Green LED off
(pressing operation
in progress).
Green LED flashes.
Green LED flashes.
Green LED flashes.
(Press device
automatically returns
to initial position.)
Red LED (3) flashes.
Red LED lit up.
Red and green LED
flash alternately.
Status/cause
Device is in SLEEP
mode.
On standby.
Automatic press cycle is
on, device ends the
pressing operation
automatically.
Insufficient battery
charge.
Retaining pin not
correctly shut.
Retaining pin has come
loose.
Device not within the
temperature range.
Device fault.
Service interval
reached.
20
Measure
Briefly press the start button (see section
6.4).
Charge or replace battery.
Insert retaining pin, or check retaining pin
and cylinder.
Insert retaining pin, or check retaining pin
and cylinder.
NOTE
The pressing operation may not have
been completed; please check and repeat
if necessary.
The device only works within a
temperature range from -10 to +50°C. If
the red LED is flashing, the device must
be moved into a warmer or colder area.
The device can be warmed to operating
temperature by means of dry runs.
Press the start button. If this is
unsuccessful, the press device is
defective.
Send the device to a specialist workshop.
NOTE
The pressing operation may not have
been completed; please check and repeat
if required.
Take the press device to be serviced.

Publicidad