CLEANING
♦ Wipe the appliance with a damp cloth impregnated
with a few drops of detergent. Do not use solvents or
products with an acidic or basic pH factor such as bleach
or abrasive products to clean the apparatus.
♦ Do not immerse the connector in water or other liquid or
place it under the tap.
♦ If the appliance is not maintained in good condition
cleaning, its surface can be degraded and inexorably
affect the life of the appliance and lead to a dangerous
situation.
Cleaning the air filter:
♦ Clean the air filters every 2 weeks. If the air filter is
blocked with dust, its effectiveness will be reduced.
♦ Washing the air filters by submerging them
♦ Carefully in warm water with a neutral detergent, rinse
them off and let them dry completely in a shady place.
♦ Install the filters carefully after having them cleaned.
After Periodic Maintenance:
♦ Switch off the appliance and remove the plug.
♦ Separate the exhaust pipe from the air and store it
carefully.
Anomalies
Product is not working
Seems device is not working
Device noise too loud
Compressor is not working
(Original instructions)
♦ Put the appliance in a dry place.
♦ Remove the batteries from the remote control and store
them carefully.
ANOMALIES AND REPAIR
♦ In the event of a fault, take the appliance to an author-
ized service center. Do not attempt to disassemble or
repair it as there may be danger.
♦ Any person who is involved with working on or breaking
into a refrigerant circuit should hold a current valid certif-
icate from an industry-accredited assessment authority,
which authorizes their competence to handle refrigerants
safely in accordance with an industry recognized assess-
ment specification.
♦ Servicing shall only be performed as recommended by
the equipment manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel shall
be carried out under the supervision of the person
competent in the use of flammable refrigerants.
♦ If any fault is detected, refer to the following table:
Causes
No power supply
Water full indicator illuminate
Indirect sunlight
Window or doors open
Filter is very dirty
Air inlet or air outlet is blocked
Room temperature is lower than the
setting one
The unit is not put on a flat surface
Heat exceeded protection is active
ENGLISH
Solutions
Switch on device
Empty water tank
Start device after empty water tank
Close courtains
Close windows
Clean or change air filter
Clean container
Change temperature setting
Change device in a flat surface
Restart the device after 3 minutes,
when temperature is lower
7