Light Sensor - Vimar ELVOX ECG3 Manual Para El Conexionado Y El Uso

Tarjeta para mando de persianas o toldos
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
4.3 Wind sensor electrical connection
Terminal number
Description
10
Wind sensor input (IN3)
11
Common (COM)
The trimmer TR1 sets the wind sensor trip threshold. Exceeding the threshold is indicated by the red LED DL1 flashing. 5 seconds after the threshold has
been exceeded the control unit will send the command to the motor.
4.4 Light sensor electrical connection
Terminal number
Description
12
Light sensor input (IN4)
14
Positive +12Vdc ( +12v)
The trimmer inside the sensor sets the light sensor trip threshold. Exceeding the threshold is indicated by the green LED DL1 flashing. 60 seconds after the
threshold has been exceeded the control unit will send the command to the motor. NB: It is necessary to respect the polarities.
18
All manuals and user guides at all-guides.com
WIND
SENSOR
REED CONTACT

LIGHT SENSOR

12V 4...20mA
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido