TEC60
9.4
Installing the tank and fuel supply line
Please observe the following instructions for the installation location:
The tank bottom must be positioned at a maximum of 0.3 m below the bot-
tom of the generator.
The top of the tank must not be higher than the top of the generator oth-
erwise the fuel will not be able to feed in.
➤ Lay the fuel line as straight as possible.
➤ Secure the tank, see fig. c, page 6 and chapter "Connecting the float" on
page 37.
9.5
Mounting the inverter
Please observe the following instructions for the installation location:
Observe the length of the extension cable from the inverter to the gener-
ator.
➤ Drill the holes as shown in fig. d, page 6.
➤ Screw on the inverter.
9.6
Mounting the control panel
Please observe the following instructions for the installation location:
Observe the length of the extension cable from the control panel to the
generator.
➤ Drill the holes as shown in fig. e, page 7.
➤ Insert the plug into the control panel.
➤ Screw on the control panel.
EN
All manuals and user guides at all-guides.com
Installation
33