Read the complete owner's manual before you begin installation.
Installation
STEP 1. Prepare the Pool
1. Manually vacuum the pool and make sure the pool filter and pump basket are clean.
2. Turn off the pool filter pump.
3. Close the pool main drain line.
4. Aim the return line fittings down.
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED CAN RESULT IN SERIOUS
INJURY OR DEATH. Ensure that your vacuum suction fittings installed in your pool for connection of
your suction-side pool cleaner are certified as being compliant with applicable safety standards such as
IAPMO SPS 4. Do not block the suction fittings with any part or your body. Do not expose your hair,
loose clothing, jewelry, etc. to any suction outlet fittings or hose ends in the pool/spa.
STEP 2. Assemble Hose Sections
Push and/or twist the connector on each hose section until they lock into position with a clicking sound
(Figure 2). Twist-lock hose cuffs have three (3) connection positions. Any of the three (3) positions are
sufficient for an air-tight seal.
j
Friction Fit Assembly
STEP 3. Connect to a Dedicated Suction Line
Turn on the pump and fill the hose with water by placing the end in front of a return inlet until it is flooded.
Turn off the pump.
For Friction Fit hoses:
1. Insert the male end of the hose (j) into the installed
Safety Vac wall fitting (sold separately).
For Twist-Lock hoses:
1. Twist-lock the male end of the hose (i) into the large end
of the extended 45° elbow (d).
2. Connect elbow to the installed Safety Vac
wall fitting (sold separately).
3. Angle the elbow toward the water surface (Figure 3).
4
WARNING
j
Twist -Lock Assembly
Figure 2.
Hose Sections
Elbow
i
i
Figure 3.
Hose Connections
d
j
i