Rothenberger ROWELD P160-630B Plus Professional Instrucciones De Uso página 24

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
When the set temperature is reached, the display jumps from "set" to "actual", and the "heat"
display blinks. The heating element is ready to use after another 10 minutes.
 Check the temperature with a temperature measurement device.
The temperature regulator is optimally set at the factory. If the actual surface temperature on the
heating element does not reflect the temperature shown, an offset can be performed. For this,
set the rocker switch to 0, press the – and + keys, and turn the rocker switch on. The display
shows "OFF", "SET" and then the set offset value. Use the – and + keys to set the offset appro-
priately, and save it by pressing – and +. Then the current value is shown again.
For P500-630B Plus:
 Switch on master switch in the control box / heating plate (the switch lights green when
power supply properly connected). Set required temperature (cf. temperature controller).
The display generally indicates the actual temperature value. In accordance with national ordi-
nances and guidelines, e. g. DVS, the heating plate is ready after maintaining the setpoint tem-
perature for at least 10 minutes.
 Check the temperature with a temperature measurement device.
Risk of serious injury! The heating plate can reach temperatures of over 300°C /
572°F! We highly recommend storing the heating plate in the designated carrying
frame immediately after use!
The welding machine is equipped with a Type 400 digital temperature controller.
The digital temperature controller has been ideally configured and set before leaving our factory.
To set temperature simply press the Fkey until "_SP" is indicated in the display. The opera-
tor can now adjust the setpoint temperature between 0-300°C / 32-572°F with the arrow keys.
If no keys are pressed, the display indicates the actual temperature, the controller automatically
sets the new temperature parameter. As long as the actual temperature is lower than the set-
point temperature, the red arrow flashes (low). If the actual value is larger than the setpoint val-
ue, the red arrow flashes (high). If the actual temperature corresponds with the setpoint temper-
ature, the green bar illuminates. Should the actual surface temperature of the heating plate not
correspond with the actual temperature indicated, it is possible to enter an "offset". To define the
offset, press and hold the F key until "InP" appears in the display (approx. 7 sec.); release
F key, then press the F key as many times as required until "oFS" appears. Correct this
value as required. To save the new settings, press and hold F key until the actual value re-
appears in the display.
Warning! Do not change any other heating plate parameters!
Factory settings:
Menü „CFG"
„S.tu"
0
„h.Pb"
1.0
„h.lt"
0.68
„h.dt"
0.17
„h.P.H"
100
„rst"
0
„P.rE"
0
„SoF"
0
„Lb.t"
0
„Lb.P"
25
„FA.P"
0
Note: The autotuning function could cause the details under "CFG" to deviate minutely. Should
hunting occur, the autotuning function can be activated while the heating plate is cold (set
the menue item "S.tu" to "2" (two) in CFG menue, the system automatically resets the pa-
rameter to "0" (zero).
20
Menü „InP"
„Ctr"
8
„tYP"
16
„FLt"
0.1
„FLd"
0.5
„dP.S."
0
„Lo.S"
0
„HI.S"
300
„oFS"
xx
„HI.A"
0
„Lo.L"
0
„HI.L"
280
ENGLISH
Menü „Out"
„AL.n"
0
„r.o.1"
0
„r.o.2"
0
„Ct.1"
20
„Ct.2"
20
„rEL."
0
Menü „PAS"
„Prot"
32

Publicidad