Flue Liner; Inner Fireplace Room Safety Distances; Outer Fireplace Safety Distances; Fireplace Room - Rocal G Serie Manual De Caracteristicas, Instalacion Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

2.2 Flue liner. It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter. The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations. This Flue liner should not be shared with other devices (see Table 1.1
Technical specifications). In cases of too much draught, when the duct exceeds 7 meters in length, or the measurement exceeds 20
Pa, the draft must be adjusted. To do this follow the steps: "D.11" to "D.13".
2.3 Type of appliance "Vermiculite" home plate at the bottom, sides and baffle plate, fire grate and ash pan. The fireplace comes
ready to install. All the inner can be removed if desired, for easier transportation and installation.
2.4. Insulating procedures.
2.4.1. Apparatus insulation. The fireplace must be insulated with insulation panels (Type A-1, EN13501-1) on its sides, back and
upper part.
2.4.2 Fireplace room insulation. It is also convenient to use insulation panels on the inner walls of the fireplace (Type A-1, EN13501-
1).
2.5. Safety distances.
2.5.1. Inner fireplace room safety distances. You must be respected the values described in 1.1 Technical characteristics
2.5.2. Outer fireplace safety distances. Anything fragile or flammable (textile, electronics, wood, paper wall, glass, chalk...) should
be separated of the appliance and respected the safety distances described in 1.1 Technical characteristics.
We must take special care in those fireplaces with wooden shelves or similar: we must prevent and avoid the possibility of hot air that
expels the device falls directly on the wood, in these cases, flammable items should be properly insulated.
2.6 Fireplace room. Fireplace room must be built with non-combustible materials and should not rest on the apparatus and the points
of contact (such as the front frame). Inside should not contain flammable or fragile materials such as wood, wallpaper, glass, chalk
paper, etc.).
2.7. Ventilation. It is imperative that the niche where the appliance is installed ventilation available.
2.7.1. Fireplace room ventilation. The appliance must be provided with an air outlet or inlet diffusers for sufficient air flow as
described in Technical characteristics
Indicative ventilation table (practicable diffuser (C4000) is equivalent to on inlnet):
Without optional
ventilation unit
G 300 LD 2
G 300 LI 3
G 450 LD 3
G 450 LI 3
2.7.2 Air supply. Air should be provided to the room where the appliance is installed. This is especially relevant when outside air is
not used and also when the door is opened for reloading with logs. This entry cannot be less than 225 cm2. Also note the simultaneous
operation with other ventilation devices and / or heating such as exhaust fans, heat pumps, etc. In these cases, the extraction must
be compensated with a corresponding air entry from outside.
If ventilation unit is used, the external air intake must be connected, if it is not possible to take air from outside, it can be connected
to a diffuser of one exit (D1001) installed as an inlet.
2.8 Changes to the device. Any intended change to the equipment must be authorized in writing by Manufacturas Rocal, S.A. We
also recommend using only original spare parts or parts recommended by Manufacturas Rocal, S.A.

3. INSTALLATION

3.1 Installation process. To proceed with the installation, follow the steps outlined in Section III of the ANNEXED document.
WARNING: The second deflector plate should be adjusted in case of draught excess, to procede follow the steps: "D.11" to "D.13".

. USE AND OPERATION

4
4.1 Fuels authorized by the manufacturer. The appliance should not be used as an incinerator and the use of fuels other than
those authorized by the manufacturer are prohibited, including lighting liquids or gels. Only natural wood logs are authorized as fuel
and it is not advisable to use resinous woods.
CAUTION:
- The maximum load allowed by the manufacturer, the measurements of the logs and the height of the
reload must be respected.
- Do not touch or manipulate any part of the appliance when in operation without a protection glove.
4.2 Pilot fire lighting. For a reasonable period of time, approximately 24 hours, it must not exceed 50% of the Maximum load allowed
by the manufacturer. Before lighting the fire, ensure that nothing delivered with the equipment has stayed inside (such as gloves,
spray paint ...)
4.3. Combustion control. The appliance has mechanisms to regulate combustion.
Minimum inlet diffuser
With optional ventilation
unit
3
4
4
4
Minimum exit diffuser
Without optional ventilation
unit
3
4
4
4
With optional ventilation
unit
4
5
5
5
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

G 300 ldG 300 liG 450 ldG 450 liG 300 ld+plus 200G 300 li+plus 200 ... Mostrar todo

Tabla de contenido