6. OPTIONAL COMPLEMENTS
Rocal offers various optional items, contact your local dealer to purchase these items. Some of the items are shown below:
Item
ECOntrol
Ventilation kit
Adapter to 4 sides frame
Decorative frame NERO
Log store
Ash vaccum cleaner
1 inlet diffuser
1 inlet narrow diffuser
2 inlets diffuser
2 inlet snarrow diffuser
3 inlets diffuser
4 inlets diffuser
1 exit diffuser
1 exit narrow diffuser
2 exits diffuser
2 exits narrow diffuser
3 exits diffuser
4 exits diffuser
7 PROBLEMS: CAUSE AND SOLUTION
Below is a table of possible anomalies, their causes and solutions:
PROBLEM
1. Rejects smoke and / or
insufficient draught
2. Excessive dirt on glass
3. Glass bleaching or colour
fading of the plate
4. Poor heating
5. Venting smoke and / or
gases from the front, bad
smell
6. Excessive draft
Code
C7000
A2082
*****
*****
C1000
ASPIRADOR
D0001
D0002
D0006
D0007
D0011
D0016
D1001
D1002
D1006
D1007
D1011
D1016
CAUSE
Incorrect duct
Lack of air supply for combustion
Incorrect position of registers
Dirty flue duct
Incorrect duct
Inappropriate fuel
Overly closed registers
Excessive temperature caused by excessive heat in
the combustion chamber
Inappropriate fuel
Insufficient load
Combustion control registers in the wrong position
First lighting
Flammable or combustible items in the enclosure or
surrounding walls of the equipment
Crack in the combustion chamber of the equipment
Incorrect duct
Combustion control registers in the wrong position
Description
Intelligent combustion control
Electric ventalation kit
Four side frame adapter
Four frame sides of 10 cm with decoration NERO
SOLUTION
Duct servicing*:
-connection
-diameter
-leaks
-insufficient length
-outdoor access
-possible elements blocking the exit
Check vents and / or outside air supply. Simultaneous
operation with other ventilation devices and / or heating
Setting the register
Contact a professional to clean flue duct. If the problem
persists, contact your dealer.
Revise section on insufficient flue (below).
Use recommended fuel
Adjust registers
Check the fuel load avoiding overheating
Adjust registers
Use recommended fuel
Adding fuel
Adjust registers
Wait for the polymerization process of the paint to finish;
this can take from one to several lightings.
Review of insulating materials such as fiberglass,
fireproof wood or any inflammable elements and replace
them.
Check for tightness and if you discover a crack, please
contact your dealer.
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
13