Sime AQUA HE 25 ErP BE Instrucciones Para El Instalador página 86

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.9.1 Operational status indication
Operational status
indication
Legend
86
Red
The multicolor signal lamp (LED) in the lockout reset button is the key
Yellow
indicating element for both visual diagnostics and interface diagnostics.
Green
LED
Visual diagnostics:
In normal operation, the different operating states are indicated in the form of color
codes according to the color code table given below.
During startup, status indication takes place according to the following table:
Color code table for multicolor signal lamp (LED)
Status
Waiting time «tw», other waiting states
Oil preheater on
Ignition phase, ignition controlled
Operation, flame o.k.
Operation, flame not o.k. (when detector
current drops below the recommended
level for reliable operation)
Extraneous light on burner startup
Undervoltage
Fault, alarm
Error code output (refer to «Error code
table»)
Interface diagnostics
...... Steady on
Off
Color code
........................................
........................................
.........................................
.........................................
Red
Yellow
Green
Color
Off
Yellow
Flashing yellow
Green
Flashing green
Green-red
Yellow-red
Red
Flashing red
Red flicker light

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aqua he 35 erp beAqua he 25 inox erpAqua he be 35 inox erp be

Tabla de contenido