LED indication
Red, slow blinking
Red, fast blinking
Orange
Orange, slow blinking
Orange, fast blinking
Other LED indications and possible causes
LED indication
All LED indicators are
off
All LED blinking green
every 5 seconds
Possible cause
Main switch is set to the OFF
position
Main switch is set to REMOTE
but no remote present
The remote switch is off (if
applied)
DC fuse blown
Power save mode
Meaning
What to do?
DC-input
Check if DC input voltage too low
voltage too
because of voltage drop across the
low
DC cables due to too long or too
narrow cables. Reduce the length
of the DC cables or use cables
with a larger gauge.
Loose or corroded connections:
Tighten the connections; burnt
cables must be corrected
immediately.
Flat battery: Disconnect the load
and recharge the battery
DC-input
Check battery voltage and switch
voltage too
off charger.
high
Starting
Normal operation
Internal
Check the airflow through the
temperature
inverter. The operation of the
too high
cooling fan may not be blocked.
Internal
Check ambient temperature
temperature
too low
What to do?
Set the main switch in ON position
Set the main switch in ON position
Close the remote operation switch
Replace the fuse
Normal operation