Ferroli Connect CRP Manual De Instalacion Y Uso página 83

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
4. Select the type of unit the Connect CRP is connected to
The available settings are:
FULL ELECTRIC
Monobloc or split heat pump, with or without stor-
age tank and without the aid of a boiler as sup-
port
HYBRID H
Hybrid system for room heating/cooling and
DHW production, consisting of heat pump and
boiler as support, with or without storage tank
HYBRID C
Hybrid system for room heating/cooling, consist-
ing of heat pump and instantaneous boiler as
support. DHW production is only with boiler.
5. Activate/deactivate the "DIGITAL INPUT" function in
accordance with the system settings.
NOTE
For correct configuration, the system configuration
must be scrupulously followed.
6. Set the number of zones with the
tons and confirm with the
Up to 8 different zones can be set. With the exception of "Zone 1" (default CRP), the other zones, if present, must be
paired to their own thermostat for correct operation (to pair an RF device, see Annex 2).
In any case, an RF device can be paired with zone 1. In this case, the Connect CRP will work only as a remote con-
troller, losing the thermostat function; Zone 1 will be managed on the temperatures detected by the paired RF device.
By default each zone has its own name assigned (modifiable at a later time):
NOTE
Zone 1: CRP
Zone 2: BEDROOM
and
but-
button.
Zone 3: BATHROOM
Zone 4: BEDROOM 2
cod. 3542B380 - Rev 00 - 05/2022
S Y S T E M T Y P E
F U L L E L E C T R I C
H Y B R I D H
H Y B R I D C
I N S T A L L E R
fig. 15 - Type of system
NOTE
For correct system setup, refer to the unit model.
D I G I T A L I N P U T
F U N C T I O N N O T A C T I V E
F U N C T I O N A C T I V E
fig. 16
I N S T A L L
Z O N E S
U S E T H E A R R O W S T O M O D I F Y
fig. 17
Zone 5: KITCHEN
Zone 6: BATHROOM 2
N U M B E R
Zone 7: DINING
Zone 8: HALL
EN
83

Publicidad

Tabla de contenido
loading

Tabla de contenido