Before using for the first time
Remove information material, adhesive tape and
1.
protective foil.
Clean the appliance.
2.
~ "Cleaning" on page 17
Electrical connection
9
CAUTION!
Do not connect the appliance to electronic
energy saver plugs.
Note: You can connect the appliance to mains-
controlled and sine-controlled inverters.
Mains-controlled inverters are used for photovoltaic
systems which are connected directly to the national
grid. Sine-controlled inverters must be used for
isolated applications. Isolated applications, e.g. on
ships or in mountain lodges, are not directly
connected to the national grid.
After installing the appliance, wait at least 1 hour
1.
before connecting it to prevent damaging the
compressor.
Connect the appliance via a correctly installed
2.
outlet.
All manuals and user guides at all-guides.com
3.
Installation and connection en-us
9
WARNING
RISK OF ELECTRIC SHOCK!
Never use multiple outlets, extension leads
or adapters.
The appliance must be correctly grounded.
Never cut through or remove the third
(ground) conductor of the power cord.
Requirements for outlets
Outlet with
110 V ... 120 V
Protective conductor
60 Hz
Fuse
10 A ... 16 A
Maximum simultaneous load
Appliance
6 A
Connect the appliance to an outlet near the
appliance.
The outlet must also be freely accessible
following installation of the appliance.
9
WARNING
RISK OF ELECTRIC SHOCK!
If the length of the power cord is inadequate,
never use multiple outlets or extension
leads.Instead, please contact Customer
Service for alternatives.
7