Mains voltage
Frequency
Max. performance
Rated power
Container capacity
Filling quantity (liquid)
Air volume (max.)
Negative pressure (max.)
Power connection data of the
power tools
Type of protection
Protective class
Suction hose connection (C-
DN/C-ID)
Length x width x height
Weight
Max. ambient temperature
Values determined to EN 60335-2-69
Sound pressure level L
Uncertainty K
pA
Hand-arm vibration value
Uncertainty K
Power cord H05VV-F 2x1,0 mm
Ap
Part no.:
EUR
6.647-263.0 7.5 m
Power cord H07RN-F 3x1,5 mm
Ap Te
Part no.:
EUR
6.649-385.0 7.5 m

Technical specifications

V
Hz
W
W
l
l
l/s
kPa
(mbar)
W
--
--
mm
mm
kg
°C
dB(A)
pA
dB(A)
m/s
2
m/s
2
2
Cable length
2
Cable length
NT 25/1
NT 25/1
Ap
Ap Te
220-240
220-240
50/60
50/60
1380
1380
1200
1200
25
25
13
13
61
61
23,0 (230) 23,0 (230) 23,0 (230) 23,0 (230)
--
100-2200
IP X4
IP X4
II
I
35
35
510 x 370
510 x 370
x 480
x 480
11,0
11,5
+40
+40
69
69
1
1
<2,5
<2,5
0,2
0,2
– 6
NT 35/1
NT 35/1
Ap
Ap Te
220-240
220-240
50/60
50/60
1380
1380
1200
1200
35
35
26
26
61
61
--
100-2200
IP X4
IP X4
II
I
35
35
510 x 370
510 x 370
x 575
x 575
11,5
12,0
+40
+40
69
69
1
1
<2,5
<2,5
0,2
0,2