Establish Communication To The Processor - Rockwell Automation Allen-Bradley SLC 5/03 Instrucciones De Instalación

Ocultar thumbs Ver también para Allen-Bradley SLC 5/03:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
All manuals and user guides at all-guides.com
8
SLC 5/03™, SLC 5/04™, and SLC 5/05™ Modular Processors
Power Supply and LED Indicators
POWER
RUN
FLT
BATT
POWER
RUN
FLT
BATT
Load Your Software
Refer to your programming software documentation.

Establish Communication to the Processor

1. Refer to the following table to establish communication between the processor
and your personal computer.
Processor
Procedure
SLC 5/03
Connect 1747-PIC from the processor to your personal computer or a 1747-CP3
cable from channel 0 of the processor to the personal computer serial port.
SLC 5/04
Connect a 1747-CP3 cable from channel 0 of the processor to the personal
computer serial port or use a 1784-KT, 1784-KTX, 1784-KT2, or 1784-PCMK
card.
SLC 5/05
Connect a 1747-CP3 cable from channel 0 of the processor to the personal
computer serial port or use a 1784-KT, 1784-KTX, 1784-KT2, or -PCMK card. For
Ethernet connection, connect channel 1 of the processor and the PC Ethernet
Card (or 1784-PCMK) to an Ethernet hub using 10Base-T cable.
Publication 1747-IN009A-ML-P
FORCE
DH485
RS232
SLC 5/03
FORCE
DH+
RS232
SLC 5/04
Indicates the LED is OFF
Indicates the LED is ON
Indicates the LED is FLASHING
Status of LED does not matter
POWER
RUN
FORCE
FLT
ENET
BATT
RS232