Australia - Conduits
57
rigid or flexible
60
Outside
2
DC=
Conduit
AC~
4
Permanently elastic sealant
Serial Number Sticker for Customer Use
61
?
Serial No. on rating plate
Fronius Inverter
Installation
58
Inside
1
3
Conduit
Seal all used conduits!
Seal every incoming and every outgoing conduit!
Conduit
Seal both conduit ends!
Application example
Fronius Inverter
Operating
Instructions
*
+
* Serial Number Sticker for Customer Use, 57 x 20 mm
**
** DRMs for
2
*
Australia
for Customer Use, 67 x 20 mm
59
Outside
DC=
Conduit
AC~
Air circulation
Condensation
NOTE! Condensation within the conduits
can damage the inverter or components of
the photovoltaic systems.
To avoid undesirable air circulation and
condensation in the conduits,
– seal all conduits being used with a per-
manently elastic sealant,
– seal every incoming and outgoing con-
duit,
– seal both conduit ends.
I9
I7
I5 IO3
IO1 GND GND D-
only Australia
4/8
2/6
CL/0
DRM's for
3/7
1/5
RG/0
1
Australia
I8
I6
I4
IO2
IO0
12
V+
12
V+
D+
I9
I7
I5 IO3
IO1 GND GND D-
4/8
2/6
CL/0
DRM's for
3/7
1/5
RG/0
Australia
I8
I6
I4
IO2
IO0
12
V+
12
V+
Inside
Conduit
**
D+