OPERATING INSTRUCTIONS
en
5.1
DC Devices
26
O P E R A T I N G I N S T R U C T I O N S | GLD20
L (A)
1
2
1
37 mm
52 mm
2
32 mm
47 mm
3
22 mm
37 mm
4
17 mm
32 mm
5
12 mm
27 mm
Only apply voltage and switch on the voltage supply once all electrical connections have
been established.
Explanation of the connection terminology used in the following tables:
BN = Brown
WH = White
BU = Blue
BK = Black
n. c. = Not connected
Q / Q = Digital output
L+ = Supply voltage (U
)
B
M = Ground
L.ON = Light switching
D.ON = Dark switching
DC: 10 ... 30 V DC,
see "Technical data", page 33
Table 3: Connection types
GLD20x-
1 = BN
2
2 = WH
3 = BU
4 = BK
3
Ø B
C
1
5.8 ... 6.7 mm
2
6.8 ... 7.7 mm
3
7.8 ... 8.2 mm
x4
xH
1
0.14 ... 1.5 mm
4
AWG26
1
2
QK
1 2
3 4
< 0.3
2
Nm
0.14 ... 0.5 mm
AWG20 ... 26
(Recommenda‐
tion: Stranded
wire)
< 0.14 mm
2
> 0.5 mm
2
8026844/2022-06-09 | SICK