10
Technical data
10.1
Technical specifications
The "Technical Data" chapter contains only an extract of the technical data of the sensor.
The complete technical data can be found on the homepage
Features
Sensing range
Min. sensing range
Maximum distance range from reflector to sensor (operating reserve 1)
Recommended distance range from reflector to sensor (operating reserve 2)
Reference reflector
Recommended sensing range for the best performance
2)
Object with 90% remission (based on standard white DIN 5033)
Emitted beam
Light sender
Type of light
Light spot size / distance
Electrical data
Supply voltage U
B
Ripple
Current consumption
Protection class
1)
Limit values
Reverse polarity protected U
B
Residual ripple max. 5 V
ss
2)
Reference voltage DC 50 V
Digital output
Output current I
max.
Circuit protection
Max. response time
Switching frequency
1)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
2)
Signal transit time with resistive load
3)
With light / dark ratio 1:1
Mechanical data
Enclosure rating
Ambient temperature, operation
8026844/2022-06-09 | SICK
Subject to change without notice
connections
OPERATING INSTRUCTIONS
www.sick.com
under the part number of the sensor.
DC
10 ... 30 V DC
1)
< 5 Vpp
≤ 30 mA
III
2)
DC
≤ 100 mA
A, B, C, D
1)
≤ 500 µs
2)
1000 Hz
3)
DC
IP67
-30 °C ... 60 °C
O P E R A T I N G I N S T R U C T I O N S | GLD20
GLD20
0.03 m
0.03 ... 20 m
0.03 m ... 16 m
PL80A
0.03 m ... 16 m
GLD20
LED
Visible red light
200 mm / 5 m
AC/DC
DC 24 ... 240 V
1)
< 10 %
≤ 50 mA, 24 V AC/DC
≤ 10 mA, 230 V AC/DC
II
2)
AC/DC
3 A @ 250 V AC
4 A @ 24 V DC
0.22 A @ 250 V DC
(UL : see
see table 17,
page
28)
≤ 15 ms
2)
10 Hz
3)
AC/DC
IP67
-30 °C ... 60 °C
en
33