STOP
Eng
Caution
Thermo King Multi-Temp host units are shipped with a 35 kPa (5 psi) holding charge of R-404A.
This holding charge of approximately 1 kg (2 lbs.) of refrigerant must be recovered.
The Spectrum remote evaporators are shipped with a 35 kPa (5 psi) holding charge of helium.
This holding charge may be safely vented into the atmosphere.
SEVERE COMPRESSOR DAMAGE will result from operating the engine before completing the
system installation which includes: installing the components, recovering the host unit holding
charge, releasing the remote unit holding nitrogen charge, soldering the refrigeration lines, leak
testing the system, evacuation and clean-up, and charging the system.
Recover Refrigerant
At Thermo King, we recognize the need to preserve the environment and limit the potential harm to
the ozone layer that can result from allowing refrigerant to escape into the atmosphere.
We strictly adhere to a policy that promotes the recovery and limits the loss of refrigerant into the
atmosphere.