Notes on the content materials (REACH)
Current information on content materials
can be found at: www.kaercher.com/
REACH
Accessories and spare parts
Only use original accessories and original
spare parts. They ensure that the appliance
will run fault-free and safely.
Information on accessories and spare parts
can be found at www.kaercher.com.
Scope of delivery
The scope of delivery for the appliance is
shown on the packaging. Check the con-
tents for completeness when unpacking. If
any accessories are missing or in the event
of any shipping damage, please notify your
dealer.
Warranty
The warranty conditions issued by our rele-
vant sales company apply in all countries.
We shall remedy possible malfunctions on
your appliance within the warranty period
free of cost, provided that a material or
manufacturing defect is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)
Safety devices
CAUTION
Missing or modified safety devices
Safety devices are provided for your own
protection.
Never modify or bypass safety devices.
Symbols on the device
(according to type of appliance)
Risk of burns, surface of appli-
ance becomes hot during oper-
ation
Risk of scalding from steam
Read operating instructions
14
Pressure controller
The pressure controller keeps the pressure
in the steam boiler as constant as possible
during operation. The heating is switched
off when the maximum operating pressure
is reached in the steam boiler and is acti-
vated if there is a pressure drop in the
steam boiler as a result of a steam removal.
Safety thermostat
The safety thermostat prevents the device
from overheating. If the pressure regulator
and the boiler thermostat fail and the unit
overheats, the safety thermostat switches
the unit off. Before resetting of the safety
thermostat, contact the responsible
KÄRCHER Customer Service.
Boiler thermostat
The boiler thermostat switches off the heat-
ing in the event of a fault; for example, if
there is no water in the steam boiler and the
temperature in the steam boiler rises.
As soon as you refill the water, the device is
ready for use again.
The safety lock seals the steam boiler from
the steam pressure present. The mainte-
nance cap is also a pressure relief valve. If
the pressure regulator is defective and the
steam pressure in the steam boiler rises,
the pressure relief valve opens and the
steam escapes through the lock.
Prior to restarting the device, contact the
responsible KÄRCHER Customer Service.
Description of the device
The maximum amount of equipment is de-
scribed in these operating instructions. De-
pending on the model used, there are
differences in the scope of delivery (see
packaging).
For the illustrations, refer to the graph-
ics page.
Illustration A
LED lights
1
Selector switch
2
Accessory storage area
3
Carrying handle
4
Water reservoir
5
English
Safety lock