Descargar Imprimir esta página

Dornbracht 41 615 979-FF Instrucciones De Montaje página 15

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
Technical data
Weight
Total (ceiling module) ............................... 57.5 kg / 127 lbs. (US)
Ceiling installation enclosure ....................... 35 kg / 77 lbs. (US)
spray module ............................................ 17 kg / 37.5 lbs. (US)
Cover ......................................................... 5.5 kg / 12 lbs. (US)
41 615 979-FF / 41 615 979-FF 0010
Maximum flow at a flow pressure of 300 kPa / 44 psi / 3 bar
TEMPEST ....................................................... 5 l/min / 1,3 gpm
AQUA CIRCLE .............................................6,8 l/min / 1,8 gpm
Minimum flow
TEMPEST ....................................................... 5 l/min / 1,3 gpm
AQUA CIRCLE ............................................... 5 l/min / 1,3 gpm
41 625 979-FF
Maximum flow at a flow pressure of 300 kPa / 44 psi / 3 bar
TEMPEST ......................................................10 l/min / 2,6 gpm
AQUA CIRCLE ............................................. 12 l/min / 3,2 gpm
QUEEN'S COLLAR ...................................... 24 l/min / 6,3 gpm
Minimum flow
TEMPEST ....................................................... 9 l/min / 2,4 gpm
AQUA CIRCLE ................................................6 l/min / 1,6 gpm
QUEEN'S COLLAR ...................................... 20 l/min / 5,3 gpm
41 630 979-FF
Maximum flow at a flow pressure of 300 kPa / 44 psi / 3 bar
TEMPEST ......................................................10 l/min / 2,6 gpm
AQUA CIRCLE ............................................. 12 l/min / 3,2 gpm
QUEEN'S COLLAR ...................................... 24 l/min / 6,3 gpm
EMBRACE ................................................. 60 l/min / 15,9 gpm
Minimum flow
TEMPEST ....................................................... 9 l/min / 2,4 gpm
AQUA CIRCLE ................................................6 l/min / 1,6 gpm
QUEEN'S COLLAR ...................................... 20 l/min / 5,3 gpm
EMBRACE: ................................................55 l/min / 14,6 gpm
Operating conditions
Permissible operating temperatures
Cold water temperature .......................... 5 – 25 °C / 41 – 77 °F
Hot water temperature ...................... 50 – 65 °C / 120 – 149 °F
Recommended hot water temperature ........ ≤ 60 °C / ≤ 140 °F
Must not be combined with continuous-flow heaters heaters.
Flow pressure
Permissible flow pressure:
341 630 979-FF ............. 100 – 500 kPa / 15 – 72 psi / 1 – 5 bar
41 625 979-FF ................100 – 500 kPa / 15 – 72 psi / 1 – 5 bar
41 615 979-FF .................100 – 500 kPa / 15 – 72 psi / 1 – 5 bar
41 615 979-FF 0010 ........100 – 500 kPa / 15 – 72 psi / 1 – 5 bar
Recommended flow pressure .............. 300 kPa / 44 psi / 3 bar
Water hardness
Recommended water hardness:
6 – 7 °dH / 107 – 125 ppm CaCO
If the water is harder, a water softener is to be installed in the
main cold water supply line.
Dimensions can be found at the end of the manual.
 / 7.5 – 8.8 °e / 10.7 – 12.5 °fH
3
Electrotechnical data
Primary connection data
Nominal voltage ................................................100 – 240 V AC
Frequency ................................................................ 50 – 60 Hz
Nominal power ...............................................................< 28 W
Standby-power ................................................................< 2 W
Ceiling module
Supply voltage ............................................................. 12 V DC
Ambient temperature ................................... ≤ 40 °C / ≤ 104 °F
Relative humidity
i
NOTICE!
Not suitable for use in a steam bath.
Light source
Technology............................................................ LED (RGBW)
Degree of protection ......................................................... IP X5
Compatibility ................................................... ZigBee Light Link
Marking ................................................................................ CE
Electrical information
Observe the regulations for protection zones according to
DIN VDE 0100, Part 701 (IEC 60364­7­701). Please conform to
national statutory regulations, where different. The following
electrical components must be installed outside safety zones
0 – 2: Power supply accessible (revision).
The product must be permanently connected to fixed
conductors.
Provided by customer
It is essential to ensure that the product can be completely
disconnected from the mains.
Residual current device
Overcurrent protection device
Dornbracht recommends consulting a system integrator.
15

Publicidad

loading

Este manual también es adecuado para:

41 615 979-ff 001041 625 979-ff41 630 979-ff