Technical data
Weight
Total (ceiling module) ............................... 57.5 kg / 127 lbs. (US)
Ceiling installation enclosure ....................... 35 kg / 77 lbs. (US)
spray module ............................................ 17 kg / 37.5 lbs. (US)
Cover ......................................................... 5.5 kg / 12 lbs. (US)
41 615 979-FF / 41 615 979-FF 0010
Maximum flow at a flow pressure of 300 kPa / 44 psi / 3 bar
TEMPEST ....................................................... 5 l/min / 1,3 gpm
AQUA CIRCLE .............................................6,8 l/min / 1,8 gpm
Minimum flow
TEMPEST ....................................................... 5 l/min / 1,3 gpm
AQUA CIRCLE ............................................... 5 l/min / 1,3 gpm
41 625 979-FF
Maximum flow at a flow pressure of 300 kPa / 44 psi / 3 bar
TEMPEST ......................................................10 l/min / 2,6 gpm
AQUA CIRCLE ............................................. 12 l/min / 3,2 gpm
QUEEN'S COLLAR ...................................... 24 l/min / 6,3 gpm
Minimum flow
TEMPEST ....................................................... 9 l/min / 2,4 gpm
AQUA CIRCLE ................................................6 l/min / 1,6 gpm
QUEEN'S COLLAR ...................................... 20 l/min / 5,3 gpm
41 630 979-FF
Maximum flow at a flow pressure of 300 kPa / 44 psi / 3 bar
TEMPEST ......................................................10 l/min / 2,6 gpm
AQUA CIRCLE ............................................. 12 l/min / 3,2 gpm
QUEEN'S COLLAR ...................................... 24 l/min / 6,3 gpm
EMBRACE ................................................. 60 l/min / 15,9 gpm
Minimum flow
TEMPEST ....................................................... 9 l/min / 2,4 gpm
AQUA CIRCLE ................................................6 l/min / 1,6 gpm
QUEEN'S COLLAR ...................................... 20 l/min / 5,3 gpm
EMBRACE: ................................................55 l/min / 14,6 gpm
Operating conditions
Permissible operating temperatures
Cold water temperature .......................... 5 – 25 °C / 41 – 77 °F
Hot water temperature ...................... 50 – 65 °C / 120 – 149 °F
Recommended hot water temperature ........ ≤ 60 °C / ≤ 140 °F
Must not be combined with continuous-flow heaters heaters.
Flow pressure
Permissible flow pressure
41 630 979-FF ............... 100 – 500 kPa / 15 – 72 psi / 1 – 5 bar
41 625 979-FF ................100 – 500 kPa / 15 – 72 psi / 1 – 5 bar
41 615 979-FF .................100 – 500 kPa / 15 – 72 psi / 1 – 5 bar
41 615 979-FF 0010 ........100 – 500 kPa / 15 – 72 psi / 1 – 5 bar
Recommended flow pressure .............. 300 kPa / 44 psi / 3 bar
Water hardness
Recommended water hardness:
6 – 7 °dH / 107 – 125 ppm CaCO
If the water is harder, a water softener is to be installed in the
main cold water supply line.
Dimensions can be found at the end of the manual.
 / 7.5 – 8.8 °e / 10.7 – 12.5 °fH
3
Electrotechnical data
Primary connection data
Nominal voltage ................................................100 – 240 V AC
Frequency ................................................................ 50 – 60 Hz
Nominal power ...............................................................< 28 W
Standby-power ................................................................< 2 W
Ceiling module
Supply voltage ............................................................. 12 V DC
Ambient temperature ................................... ≤ 40 °C / ≤ 104 °F
Relative humidity
i
NOTICE!
Not suitable for use in a steam bath.
Light source
Technology............................................................ LED (RGBW)
Degree of protection ......................................................... IP X5
Compatibility ................................................... ZigBee Light Link
Marking ................................................................................ CE
Electrical information
Observe the regulations for protection zones according to
DIN VDE 0100, Part 701 (IEC 60364­7­701). Please conform to
national statutory regulations, where different. The following
electrical components must be installed outside safety zones
0 – 2: Power supply accessible (revision).
The product must be permanently connected to fixed
conductors.
Provided by customer:
It is essential to ensure that the product can be completely
disconnected from the mains.
Residual current device
Overcurrent protection device
Dornbracht recommends consulting a system integrator.