There is sound of
running water
during the running
of air conditioner.
A slight "click" sound
is heard at the of
start - up or shut - down.
The indoor unit
makes abnormal
sound.
There are water
drops over the
surface of the
indoor unit.
During the cooling
operation, the indoor
unit outlet sometimes
will blow out mist.
¡t_
lmmediately stop all operations and cut off the power supply,
· contact our Service center locally in following situations .
.._ Hear any harsh sound or smell any awful odor during running .
.._ Abnormal heating of power cable and plug occurs .
.._ The unit or remate controller has any impurity or water .
.._ Air switch or leakage protection switch is often disconnected.
www.infiniton.es
©@
• When the air conditioner is started up or stopped, or the
compressor is started up or stopped during the running,
)1
sometimes the "hissing" sound of running water can be
heard. _. This is the sound of the flow of the refrigerant,
not a malfunction.
• Due to temperature changes, panel and other parts will swell,
11
causing the sound of friction.
_. This is normal, not a fault.
• T he sound of fan or compressor relay switched on or off.
When the defrosting is started or stop running, it will create
sound.
_. That is due to the refrigerant
They are not malfunctions.
• Too much dust accumulation
unit may result in fluctuation of the sound.
- Clean the air filters in time.
• Too much air noise when "Strong wind" is turned on.
-This is normal, if feeling uncomfortable, please
deactivate the "Strong wind" function.
• When ambient humidity is high, water drops will be
accumulated around the air outlet or the panel, etc.
---+ This is a normal physics phenomenon.
• Prolonged cooling run in open space produces water drops.
-Glose the doors and windows.
• Too small opening angle of the louver blades may also result
in water drops at the air inlet.
-lncrease the angle of the louver blades.
• When the indoor temperature and humidity are high, it happens
11
sometimes.
_. This is because the indoor air is cooled rapidly. After it runs
for sorne time, the indoor temperature and humidity will be
reduced and the mist will disappear.
Troubleshooting
flows
on
the air filter of the indoor
- 13 -
to reverse direction.